Power and Control
Toll free phone numbers:
(877)696-8062

Email:
sales@pacdist.com Sales & Service
Home | About PAC | Product Lines | Contact | Quote | Newsletter
Transformer Products:

Industrial Control Transformers

Type FB Encapsulated Transformers

Type FH Ventilated Transformers

High Voltage General Purpose

Padmounted Transformers

Unit Substation and HV Voltage Power Transformers

VPI and VPI/Epoxy shielded Transformers

Specialty Transformers

ABS Marine-Duty Transformers

Accessories

Federal Pacific Transformer logo    ⋅ Industrial Control Transfomer
⋅ Encapsulated 600 Volt Class ⋅ Ventilated 600 Volt Class
⋅ High Voltage General Purpose Transformer
⋅ Padmounted Transformer
⋅ Unit Substation and High Voltage Power Transformer
⋅ Vacuum Pressure Impregnated (VPI) and VPI/Epoxy Shielded
⋅ NEMA TP-1, TP-2, TP-3 Rated ⋅ Specialty Transformers
⋅ ABS Certified Marine Duty Transformers
Industrial Control Transformer

Industrial Control Transformers

· 50 through 750 VA
· Epoxy Encapsulated Coils
· Copper Wound
· Optional Primary Fusing
· Single Phase
· 50/60 Hz.
· UL® 506 Listed
· CSA Certified


KvaGroup A
Primary Volts
240x480, 230x460, 220x440
Secondary Volts 120,115,110
50/60 Hz
Group B
Primary Volts
240x480
Secondary Volts 24
50/60 Hz
Group C
Primary Volts
120x240
Secondary Volts 24
50/60 Hz
Group D
Primary Volts
115 x 230
Secondary Volts 24
50/60 Hz
Group E
Primary Volts
550/575/600
Secondary Volts 110,115,120
50/60 Hz
25 FA025JK    
50FA050JKFB050JKFC050JKFD050JKFE050XK
75FA075JKFB075JKFC075JKFD075JKFE075XK
100FA100JKFB100JKFC100JKFD100JKFE100XK
150FA150JKFB150JKFC150JKFD150JKFE150XK
200FA200JKFB200JKFC200JKFD200JKFE200XK
250FA250JKFB250JKFC250JKFD250JKFE250XK
300FA300JKFB300JKFC300JKFD300JKFE300XK
350FA350JKFB350JKFC350JKFD350JKFE350XK
500FA500JKFB500JKFC500JKFD500JKFE500XK
750FA750JK   FE750XK
1000FA1000JK
FA1000E
    
1500FA1500E    
2000FA2000E    
3000FA3000E    
5000FA5000E    

sales@pacdist.com Call for a quote (877)696-8062


KvaGroup F
Primary Volts
208/277
Secondary Volts 120
50/60 Hz
Group G
Primary Volts
208/277
Secondary Volts
120
50/60 Hz
Group H
Primary Volts
230/460/575
Secondary Volts
95,115
50/60 Hz
Group I
Primary Volts
380/400/415
Secondary Volts
110 X 120
50/60 Hz
Group J
Primary Volts
200/220/440
208/230/460,240/480
Secondary Volts 23/110
24/115, 25/120
50/60 Hz
25     
50FF050XKFG050XKFH050XXFI050XJFJ050XK
75FF075XKFG075XKFH075XXFI075XJFJ075XK
100FF100XKFG100XKFH100XXFI100XJFJ100XK
150FF150XKFG150XKFH150XXFI150XJFJ150XK
200FF200XKFG200XKFH200XXFI200XJFJ200XK
250FF250XKFG250XKFH250XXFI250XJFJ250XK
300FF300XKFG300XKFH300XXFI300XJFJ300XK
350FF350XKFG350XKFH350XXFI350XJFJ350XK
500FF500XKFG500XKFH500XXFI500XJFJ500XK
750FF750XKFG750XKFH750XX FJ750XK
1000 FG1000EFH1000E  
1500 FG1500EFH1500E  
2000 FG2000EFH2000E  
3000 FG3000EFH3000E  
5000 FG5000EFH5000E  

sales@pacdist.com Call for a quote (877)696-8062


KvaGroup K
Primary Volts
240 X 480
Secondary Volts
120 X 240
50/60 Hz
Group L
Primary Volts
240/416/480/600
230/400/460/575
220/380/440/550,208/500
Secondary Volts
99/120/130
95/115/125
91/110/120
85/100/110
50/60 Hz
Group M
Primary Volts
240 x 480 230 x 460 220 x 440
Secondary Volts
120 x 240, 115 x 230, 110 x 220
50/60 Hz
Group N
Primary Volts
240/347/380
Secondary Volts 120 x 240
50/60 Hz
25    
50FK050JJFL050JL  
75FK075JJFL075JL  
100FK100JJFL100JL  
150FK150JJFL150JL  
200FK200JJFL200JL  
250FK250JJFL250JL  
300FK300JJFL300JL  
350FK350JJFL350JL  
500FK500JJFL500JL  
750FK750JJFL750JL  
1000  FM1000EFN1000E
1500  FM1500EFN1500E
2000  FM2000EFN2000E
3000  FM3000EFN3000E
5000  FM5000EFN5000E

sales@pacdist.com Call for a quote (877)696-8062


Type FB Encapsulated Transformer

Type FB Encapsulated Transformers


· Totally Enclosed, Non-Ventilated
· UL® Listed for Indoor/Outdoor Use
· 115° C Temperature Rise
· Standard Voltages in Stock
· Custom Designs Available

General Purpose Single Phase, 60 Hz Transformer
Type Pri
Sec
KVA
120 x 240
120/240
No Taps
208
120/240
With Taps
240 x 480
120/240
No Taps
240 x 480
120/240
With Taps
277
120/240
With Taps
480
120/240
With Taps
600
120/240
With Taps
FB .050
.075
.100
.150
.250
.500
.750
1
1.5
2
3
5
7.5
10
15
 
 
 
 
 
 
 
SE120N1F
SE120N1.5F
SE120N2F
SE120N3F
SE120N5F
SE120N7.5F
SE120N10F
SE120N15F
 
 
 
 
 
 
 
SE201D1F
SE201D1.5F
SE201D2F
SE201D3F
SE201D5F
SE201D7.5F
SE201D10F
SE201D15F
SE2N.050F
SE2N.75F
SE2N.100F
SE2N.150F
SE2N.250F
SE2N.500F
SE2N.750F
SE2N1F
SE2N1.5F
SE2N2F
SE2N3F
SE2N5F
SE2N7.5F
SE2N10F
SE2N15F
 
 
 
 
 
 
 
 
 
 
SE2T3F
SE2T5F
SE2T7.5F
SE2T10F
SE2T15F
 
 
 
 
 
 
 
SE271D1F
SE271D1.5F
SE271D2F
SE271D3F
SE271D5F
SE271D7.5F
SE2D10F
SE2D15F
 
 
 
 
 
 
 
SE481D1F
SE481D1.5F
SE481D2F
SE481D3F
SE481D5F
SE481D7.5F
SE481D10F
SE481D15F
 
 
 
 
 
 
 
SE61D1FS
SE61D1.5FS
SE61D2FS
SE61D3FS
SE61D5FS
SE61D7.5FS
SE61D10FS
SE61D15FS

sales@pacdist.com Call for a quote (877)696-8062

Type FH Ventilated Transformer

Type FH Ventilated Transformers


· UL® Listed
· Ventilated Enclosure
· Weather Shields Available for NEMA 3R Outdoor Applications
· 150° C Temperature Rise
· Optional 80° C and 115° C Rise
· Standard Voltages in Stock Including Copper, Aluminum, Electrostatically Shielded, Low Temperature Rise and K-Factor Rated
· Custom Designs Available

TYPE FH: 150 DEGREES C RISE-220 DEGREES C INSULATION SYSTEM
INDOOR VENTILATED-FLOOR MOUNTED
HV TAPS: 1-5% FCAN, 1-5% FCBN
VOLTAGES-PRIMARY-DELTA SECONDARY - WYE, 60Hz
MOTOR
HP
KVA 230-230Y 230-460Y 460-230Y 460-460Y
3 & 5
7.5
10
15
20
7.5
11
15
20
27
7.5AEMD
11AEMD
15AEMD
20AEMD
27AEMD
7.5AFMD
11AFMD
15AFMD
20AFMD
27AFMD
7.5CEMD
11CEMD
15CEMD
20CEMD
27CEMD
7.5CFMD
11CFMD
15CFMD
20CFMD
27CFMD
25
30
40
50
60
34
40
51
63
75
34AEMD
40AEMD
51AEMD
63AEMD
75AEMD
34AFMD
40AFMD
51AFMD
63AFMD
75AFMD
34CEMD
40CEMD
51CEMD
63CEMD
75CEMD
34CFMD
40CFMD
51CFMD
63CFMD
75CFMD
75
100
125
150
200
93
118
145
175
220
93AEMD
118AEMD
145AEMD
175AEMD
220AEMD
93AFMD
118AFMD
145AFMD
175AFMD
220AFMD
93CEMD
118CEMD
145CEMD
175CEMD
220CEMD
93CFMD
118CFMD
145CFMD
175CFMD
220CFMD
250
300
400
500
600
700
275
330
440
550
660
750
275AEMD
330AEMD
440AEMD
550AEMD
660AEMD
750AEMD
275AFMD
330AFMD
440AFMD
550AFMD
660AFMD
750AFMD
275CEMD
330CEMD
440CEMD
550CEMD
660CEMD
750CEMD
275CFMD
330CFMD
440CFMD
550CFMD
660CFMD
750CFMD

 

TYPE FH: 150 DEGREES C RISE-220 DEGREES C INSULATION SYSTEM
INDOOR VENTILATED-FLOOR MOUNTED
HV TAPS: 1-5% FCAN, 1-5% FCBN
VOLTAGES-PRIMARY-DELTA SECONDARY - WYE, 60Hz

MOTOR
HP
KVA 230-575Y 460-575Y 575-230Y 575-460Y 575-575
3 & 5
7.5
10
15
20
7.5
11
15
20
27
7.5AHMD
11AHMD
15AHMD
20AHMD
27AHMD
7.5CHMD
11CHMD
15CHMD
20CHMD
27CHMD
7.5DEMD
11DEMD
15DEMD
20DEMD
27DEMD
7.5DFMD
11DFMD
15DFMD
20DFMD
27DFMD
7.5DHMD
11DHMD
15DHMD
20DHMD
27DHMD
25
30
40
50
60
34
40
51
63
75
34AHMD
40AHMD
51AHMD
63AHMD
75AHMD
34CHMD
40CHMD
51CHMD
63CHMD
75CHMD
34DEMD
40DEMD
51DEMD
63DEMD
75DEMD
34DFMD
40DFMD
51DFMD
63DFMD
75DFMD
34DHMD
40DHMD
51DHMD
63DHMD
75DHMD
75
100
125
150
200
93
118
145
175
220
93AHMD
118AHMD
145AHMD
175AHMD
220AHMD
93CHMD
11CHFMD
145CHMD
175CHMD
220CHMD
93DEMD
118DEMD
145DEMD
175DEMD
220DEMD
93DFMD
118DFMD
145DFMD
175DFMD
220DFMD
93DHMD
118DHMD
145DHMD
175DHMD
220DHMD
250
300
400
500
600
700
275
330
440
550
660
750
275AHMD
330AHMD
440AHMD
550AHMD
660AHMD
750AHMD
275CHMD
330CHMD
440CHMD
550CHMD
660CHMD
750CHMD
275DEMD
330DEMD
440DEMD
550DEMD
660DEMD
750DEMD
275DFMD
330DFMD
440DFMD
550DFMD
660DFMD
750DFMD
275DHMD
330DHMD
440DHMD
550DHMD
660DHMD
750DHMD

sales@pacdist.com Call for a quote (877)696-8062

High Voltage General Purpose Transformer

High Voltage General Purpose


· Free-Standing Indoor Ventilated Enclosure
· Optional NEMA 3R Outdoor Enclosure
· Optional 80° C or 115° C Temperature Rise
· Standard Aluminum or Optional Copper Windings

sales@pacdist.com Call for a quote (877)696-8062

Padmounted Transformer

Padmounted Transformers


· Tamper-Resistant
· Compartmentalized
· Indoor or Outdoor Application
· Patented Air Baffling System
· Wide Selection of Options and Accessories

sales@pacdist.com Call for a quote (877)696-8062

Unit Substation and HV Voltage Power Transformer

Unit Substation and HV Voltage Power Transformers


· Free-Standing Indoor Ventilated Enclosure
· Optional NEMA 3R Outdoor Enclosure
· Optional 80° C or 115° C Temperature Rise
· Standard Aluminum or Optional Copper Windings

sales@pacdist.com Call for a quote (877)696-8062

VPI and VPI/Epoxy shielded Transformer

VPI and VPI/Epoxy shielded Transformers


· Polyester Coil Encapsulation Plus Opt. Epoxy Sheild
· Outstanding Environmental Protection
· Advantages Over Cast Coil Include:
Higher Thermal Overload Capabilities, Significantly
Lower Cost, Less Weight, Smaller Size, Maximum
Design Flexibility and Elimination of Epoxy
Cracking Due to Thermally-Induced Stress

sales@pacdist.com Call for a quote (877)696-8062

Specialty Transformer 600 Volt Class Through 34.5 kV Class 50 VA Through 10000 kVA

Specialty Transformers


· Application-Engineered Specialty Transformers
· 600 Volt Class Through 34.5 kV Class 50 VA Through 10000 kVA

sales@pacdist.com Call for a quote (877)696-8062

ABS Marine-Duty Transformer

ABS Marine-Duty Transformers


Commercial and Military Ship Applications
Type FH, 600 VAC, Single-Phase and Three-Phase Transformers
· Distribution
· Motor Drive Isolation
· 12-24 Pulse Source for Rectification Circuits
Medium Voltage Dry-Type Transformers 5-15 kV, BIL Ratings 30-95 kV
· Unit Substations
· Rectifier Applications
· High Voltage General Purpose

sales@pacdist.com Call for a quote (877)696-8062

Federal Pacific Transformer Accessories

Accessories


· Terminal Lug Kits
· Weather Shield Kits
· Wall Mount Brackets

sales@pacdist.com Call for a quote (877)696-8062