The various dayform shapes of
our Flood and Area lighting
fixtures may be distinctly
different, but they share Ruud
Lighting dependability and
value. Ruud Lighting has the
right luminaire and optical
system for the job, whether the
project calls for:
• Area Lighting
• General Floodlighting
• Safety and Security Lighting
Micro Flood
We’ve expanded our popular
Micro Flood (NS Series)
product line to now include
lamp choices through 400 watt.
A simplified, low-cost housing
and lens-frame design
incorporates the versatility of
three optical choices in
standard flood, cutoff flood or
wide flood.
Square Flood and Area
Our Square Flood and Area line
offers fixtures with optical
systems designed to meet
specific lighting-application
needs. These computer-
designed systems give
optimum performance.
Wedge Light
The distinctive, streamlined
style of the Wedge Light,
available in two optical
systems, provides outstanding
performance.
Square Dome Area Lights
These area lights feature a
unique style and dayform
appearance. The luminaires
include a choice of three high-
performance optical systems
that feature the benefits of
optimized vertical pulse start
lamps for greatest efficacy and
life.
Rectangular Flood
and Area
Available with four Flood and
two Area optical systems, the
Rectangular Series offers a
functional alternative for low-
profile sign, flagpole and
general illumination
applications.
NPPG 102
Flo
o
d
&
A
rea
102
22" square 100W CF Series Fixtures
(Cutoff Flood light)
Page 116
Rectangular 70 & 100W MH
LPN Series Fixture
Page 144
AC Series Fixtures (Area Cutoff)
Page 122
www.ruudlighting.com
pg_0002
NPPG 103
NPPG 103
103
General Floodlight Optics
Standard Floodlight
FS Series (Page 115)
The FS Series is typically installed with a 45° to 60° tilt above horizontal to provide a
wide coverage of illumination. The FS Series is ideal for signs, large open areas and
facade applications.
Narrow Beam Cutoff Floodlight
CN Series (Page 117)
The specular aluminum reflector of the CN Series provides narrow vertical and wide
horizontal distribution. Recommended tilt of this fixture is 60° above horizontal. The
CN Series is ideal for lighting large sports fields, building facades and signs.
FS Series, 60° tilt above horizontal
Typical isofootcandle
distribution at grade
CN Series, 60° tilt above horizontal
Typical isofootcandle
distribution at grade
Micro Flood-Standard
NSF Series (Page 107)
This compact standard flood fixture typically is installed with a 45- to 60-degree tilt
above horizontal. The NSF is ideal for large, open areas and facade applications.
NSF Series, 60° tilt from horizontal
Typical isofootcandle
distribution at grade
Micro Flood-Wide
NSW Series (Page 109)
For floodlighting applications that require extra-wide lateral distribution, the NSW
Series fixture is installed from a 15- to 25-degree tilt above horizontal to prevent glare
and ensure optimal performance. The NSW is ideally suited for roadway applications,
parking areas or security.
NSW Series, 20° tilt from horizontal
Typical isofootcandle
distribution at grade
NS Series, 60° tilt above horizontal
Typical isofootcandle
distribution at grade
Cutoff Floodlight Optics
Micro Flood-Cutoff
NSC Series (Page 108)
The NSC Series produces narrow vertical and wide horizontal distribution and
typically is installed with a 45- to 60-degree tilt-angle. The optical system is designed
with sharp cutoff to reduce glare for pedestrians and vehicular traffic. The NSC is
designed to work optimally in parking lot and outdoor sports area.
NSC Series, 60° tilt from horizontal
Typical isofootcandle
distribution at grade
Cutoff Floodlight
CF Series (Page 116)
This cutoff luminaire has an optical system specifically designed to assure maximum
main beam projection, while minimizing glare and spill light. It is generally positioned
with a 15 to 25° tilt above horizontal. The CF Series can be used for parking lots, auto
sales lots, volleyball courts and tennis courts.
CF Series, 20° tilt above horizontal
Typical isofootcandle
distribution at grade
Micro Flood
NS Series (Page 110)
The diffuse reflector of the NS Series is designed to provide conventional floodlighting
for a variety of applications and mounting positions.
www.ruudlighting.com
pg_0003
NPPG 104
NPPG 104
PN Series, 60° tilt above horizontal
Typical isofootcandle
distribution at grade
PM Series, 60° tilt above horizontal
Typical isofootcandle
distribution at grade
104
Parabolic Floodlight Optics
Micro Medium/Narrow Axial Parabolic Flood
NSM and NSN Series (Page 110)
Featuring axially symmetric parabolic reflectors with centered lamps, these additions to the Parabolic Floodlight line are available with two light distributions. Medium parabolic
(NSM Series) produces a moderately tight beam of light. Narrow parabolic (NSN Series) features a tight, high-precision beam. The NSM and NSN Series are excellent choices for
lighting tall, narrow subjects such as flagpoles, steeples, columns and signs.
NSM Series, 60° tilt from horizontal
Typical isofootcandle
distribution at grade
NSN Series, 60° tilt from horizontal
Typical isofootcandle
distribution at grade
Mini Medium/Narrow Axial Lamp Parabolic Flood
MAM and MAN Series (Page 120)
Two light-distribution systems are offered in these 12-inch fixtures that feature axially symmetric parabolic reflectors with centered lamps. The MAM offers medium distribution; the
MAN features a narrow beam. The MAM and MAN Series are ideal for lighting tall, narrow subjects, including flag poles, signs, and architectural details.
MAM Series, 60° tilt from horizontal
Typical isofootcandle
distribution at grade
MAN Series, 60° tilt from horizontal
Typical isofootcandle
distribution at grade
Parabolic Medium and Narrow Floodlights
PM and PN Series (Pages 118–119)
The smooth aluminum reflector of both the Medium and the Narrow optics have the same shape. The difference in their performance is achieved by varying the reflector material.
The Medium Parabolic Floodlight uses a diffuse reflector; the Narrow Parabolic Floodlight uses a bright anodized reflector. The PM and PN Series are ideal for illuminating tall,
narrow subjects such as flagpoles, steeples, columns and signs.
www.ruudlighting.com
pg_0004
NPPG 105
NPPG 105
105
Area Light Optics
Vertical Forward Throw
VFT Series (Page 123)
The VFT Series features a 70° main beam. Inside the housing, the lamp is tilted
20° from vertical toward house-side. It provides excellent uniformity, low nadir
candlepower and great forward and lateral distribution. The VFT Series is ideal for
use in wide roadway areas and large parking areas.
VFT Series, 0° tilt from horizontal
Typical isofootcandle
distribution at grade
Area Cutoff Light
AC Series (Page 122)
This compact forward-throw reflector has a main beam of 60°+ from vertical
(30° from horizontal), providing wide lateral distribution and improved uniformities.
A Backlight Shield accessory (standard on Wall Mount) permits precise cutoff
adjustability. The AC Series can be used for parking lots, auto sales lots and
tennis courts.
AC Series, 0° tilt from horizontal,
no backlight shield
Typical isofootcandle
distribution at grade
Parking/Roadway Light
PR Series (Page 124)
The PR Series reflector provides wide side to side and moderate front distribution. The
12-inch square housing has a Type III asymmetric distribution pattern. The 16-inch
square housing is Type III. The 22-inch square housing is Type II. The PR Series is
ideally suited for roadway applications, parking areas or for building-
mounted security lighting.
PR Series, 0° tilt above horizontal
Typical isofootcandle
distribution at grade
Quadrate Vertical and Horizontal Lamp Post Top Lights
QV and QH Series (Pages 126–127)
The QV and QH Series fixtures are available with two mounting styles, and provide great quadrate distribution and uniformities with optimum pole spacings. The QV and QH
Series are ideal for parking lots.
Square Tube QV Series,
0° above horizontal
Typical isofootcandle
distribution at grade
Round Tube QH Series,
0° above horizontal
Typical isofootcandle
distribution at grade
Vertical Parking/Roadway Light
VPR Series (Page 125) The VPR Series
fixture features a 70° main beam. Inside the housing, the lamp is tilted 20° from
vertical toward the house-side of the fixture. It provides low nadir candlepower and
great lateral distribution.The Vertical Parking/Roadway is ideal for use in wide
roadway areas and large parking areas.
VPR Series, 0° tilt above horizontal
Typical isofootcandle
distribution at grade
www.ruudlighting.com
pg_0005
The new Micro Flood (NS Series) combines the best
in high-performance optical systems and a compact
housing size at an economical price.
This innovative floodlight is available in a choice of
three optical systems, Standard Flood, Cutoff Flood
and Wide Flood, in a compact 14-inch square x
6.375-inch deep housing size and with HID wattages
150 through 400.
The Micro Flood features a die-cast
aluminum lens frame and housing with the
same high quality and exclusive
DeltaGuard
®
paint finish, as our other
floodlights. It also offers great light
distribution for general floodlighting
applications in a compact size.
The original Micro Flood (9.75"W x 6.25"H
x 4.75"D housing) is also available in lower
HID wattages from 35 through 150 watt and
compact fluorescent lamps in single or twin
13-watt twin tube, 26-watt quad-tube or 32- and
42-watt triple tube. A new Axial Parabolic reflector
version, in two beam angles (NSM and NSN Series),
is offered in 70- or 100-watt G-12 tubular metal
halide.
NPPG 106
M
icro
Flo
o
d
HID lamp supplied with fixture
Precise reflector systems using various high
efficiency pre-finished reflector sheets for
optimized lighting results
Constant wattage high power factor ballast
assembly is heat sunk to the aluminum
housing for increased life (patents pending)
Ballast compartment cover restricts access
during relamping providing added safety
Integral lens frame hinge
Copper-free aluminum die-cast door frame
Tempered glass lens for
maximum impact resistance
Black stainless steel
captive fasteners
Yoke Mount Option
Micro Flood Catalog Number Logic
NOTE: See product pages for availability
NS
F
4
4
40
M
NS = Micro Flood
Lamps/Ballasts
2 = Fluorescent
3 = Mercury Vapor
4 = Metal Halide
5 = High Pressure Sodium
6 = Pulse Start Metal Halide
7 = G12 Ceramic Metal Halide
Wattages
03 = 35W HPS
05 = 50W MH or HPS
07 = 70W MH or HPS
10 = 100W MH, MV or HPS
13 = 13W compact fluorescent
15 = 150W HPS
17 = 175W MH
25 = 250W MH or HPS
26 = Twin 13W compact fluorescent
32 = 320W PSMH
40 = 400W MH or HPS
Voltages
1 = 120V
2 = 277V
27= 277V Reactor
3 = 208V
4 = 240V
5 = 480V
6 = 347V (Canada only)
D = Dual-volt (120/277V)
M = Quad-volt (120/208/240/277V)
T = Tri-volt (120/277/347V)
(Canada only)
NOTE: D, M or T voltage suffix are
factory set at highest voltage.
Optical Systems
F = Standard Flood
C = Cutoff Flood
M = Axial Parabolic Medium
N = Axial Parabolic Narrow
W = Wide Flood
Blank = Low wattage Micro Flood
Mountings
3 = 2" Adjustable Fitter
(NSF, NSC, & NSW only)
4 = Yoke Mount
(NSF, NSC, & NSW only)
6 = 1/2" Adjustable Fitter
(low wattage NS only)
Capacitor, starter and other electrical
components are strategically located and
heat sunk to the housing to increase life
Internal ribbing structure to prevent
any wall distortion or sagging
4kv rated porcelain lamp socket
Copper-free aluminum die-cast housing
DeltaGuard
®
finish,
featuring E-coat epoxy primer
and bronze ultra-durable
powder topcoat
Silicone gasket to assure
a lifetime seal
106
www.ruudlighting.com
pg_0006
NPPG 107
NPPG 107
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
14" 320W PSMH NSF
*
632-M
3
= 2" Adjustable Fitter
14" 175W MH NSF
*
417-M
4
= Yoke Mount
14" 250W MH NSF
*
425-M
14" 400W MH NSF
*
440-M
14" 150W HPS NSF
*
515-M
14" 250W HPS NSF
*
525-M
14" 400W HPS NSF
*
540-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH and 400W MH
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( 320W P SM H only )
27
480V ballast (Not available on 150W HPS)
5
Tri-volt ballast
T
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter )
NOTE: n/a 480V
27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 111)
For fixtures w/480V
5 P
Accessories: (Field-installed)
Catalog #
Deep Baffle
DB-14
Wire Guard
FWG-14
Glare Shield
GS-14
Button Photocell
( Fi e ld-i ns ta ll e d i n f ix tur e s w i th 2" A djus t abl e Fi tt er )
Catalog #
For fixtures w/120V
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 106
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 111
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
For general-purpose floodlighting, the compact, economical NSF Series is typically
installed with a 45- to 60-degree tilt above horizontal to provide wide coverage of
illumination. This Standard Micro Flood is ideal for lighting large open areas and
facades. The 14-inch square x 6.375-inch deep fixture is designed for easy installation
and serviceability.
107
Micro Flood–Standard
Lamp
Included!
NSF Series Order Information
NSF Series
Yoke Mount
V ER TI CA L
H ORI Z ONTA L
400 0
320 0
240 0
160 0
80 0
480 0
560 0
640 0
720 0
800 0
880 0
960 0
0
ANG LE ( IN DE G RE E S ) - V E RTI CA L & HOR IZ ON TAL
16
32
48
64
16 3 2 4 8 6 4
Candlepower Trace through origin
400W MH Micro Flood-Standard
NEMA Type 7H x 6V.
0 20’ 40’
40’ 20’
60’
60’
0 6.1 12.2
12.2 6.1
18.3
18.3
6.1
0m
6.1
12.2
18.3
24.4
30.5
20’
0’
20’
40’
60’
80’
100’
.3
.5
1
3
5
Isofootcandle plot of 400W MH
Micro Flood-Standard at 25' (7.6m)
mounting height, and 60° tilt
above horizontal.
12.8" (325 mm)
14.0" (356 mm)
6.0" (152 mm)
www.ruudlighting.com
pg_0007
NPPG 108
NPPG 108
V E RT I CA L
HOR I
Z ONT A L
150 00
120 00
90 00
60 00
30 00
180 00
210 00
240 00
270 00
300 00
330 00
360 00
0
ANG LE ( IN D EG RE E S ) - V E RT IC AL & HO RIZ O NTA L
16
32
48
6 4
16 3 2 48 64
The NSC Series fixture provides narrow vertical and wide horizontal distribution in a
compact housing size. The Micro Flood–Cutoff is typically installed with a 45- to
60-degree tilt-angle. The optical system is designed with sharp cutoff to reduce glare
for pedestrians and vehicular traffic. The 14-inch square x 6.375-inch deep fixture is
designed for easy installation and serviceability.
108
Lamp
Included!
NSC Series Order Information
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
1 4" 320W PSMH NSC
*
632-M
3
= 2" Adjustable Fitter
1 4" 175W MH NSC
*
417-M
4
= Yoke Mount
1 4" 250W MH NSC
*
425-M
1 4" 400W MH NSC
*
440-M
1 4" 150W HPS NSC
*
515-M
1 4" 250W HPS NSC
*
525-M
1 4" 400W HPS NSC
*
540-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH and 400W MH
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
(32 0W P SM H onl y )
27
480V ballast (Not available on 150W HPS)
5
Tri-volt ballast
T
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter )
NOTE: n/a 480V
27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 111)
For fixtures w/480V
5 P
Accessories: (Field-installed)
Catalog #
Deep Baffle
DB-14
Wire Guard
FWG-14
Button Photocell
( Fi el d-i nst a ll ed in fi x tur e s w it h 2" Ad jus ta bl e Fit te r )
Catalog #
For fixtures w/120V
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 106
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 111
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
NSC Series
2" Adjustable
Fitter
Candlepower Trace through origin
400W MH Micro Flood-Cutoff
NEMA Type 6H x 5V.
0 6. 1 12 .2
1 2. 2
18. 3 6.1
18 .3
0 20’ 40’
40 ’ 20 ’
60 ’
60’
6 .1
0 m
6 .1
12. 2
18. 3
. 3
. 5
1
5
3
24. 4
20’
0 ’
20’
40’
60’
80’
Isofootcandle plot of 400W MH
Micro Flood-Cutoff at 25' (7.6m)
mounting height, and 60° tilt
above horizontal.
Micro Flood–Cutoff
12.8" (325 mm)
14.0" (356 mm)
6.0" (152 mm)
www.ruudlighting.com
pg_0008
NPPG 109
NPPG 109
V E RTI CA L
HORI Z ONT A L
0
ANG L E ( I N D E GRE E S ) - V E RT IC AL & HO RI ZO NT AL
16
32
48
64
16 32 48 64
4000
3200
2400
1600
800
4800
5600
6400
7200
8000
8800
9600
For floodlighting applications where extra-wide lateral distribution is desired, the NSW
Series is designed to provide maximum side-to-side coverage. This fixture typically is
installed from a 15- to 25-degree tilt above horizontal to prevent glare and ensure
optimum performance. The 14-inch square x 6.375-inch deep floodlight is designed
for easy installation and serviceability.
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
14" 320W PSMH NSW
*
632-M
3
= 2" Adjustable Fitter
14" 175W MH NSW
*
417-M
4
= Yoke Mount
14" 250W MH NSW
*
425-M
14" 400W MH NSW
*
440-M
14" 150W HPS NSW
*
515-M
14" 250W HPS NSW
*
525-M
14" 400W HPS NSW
*
540-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH and 400W MH
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( 320W P SM H only )
27
480V ballast (Not available on 150W HPS)
5
Tri-volt ballast
T
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter )
NOTE: n/a 480V
27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 111)
For fixtures w/480V
5 P
Accessories: (Field-installed)
Catalog #
Wire Guard
FWG-14
Glare Shield
GS-14
Button Photocell
( Fi e ld-i ns ta ll e d i n f ix tur e s w i th 2" A djus t abl e Fi tt er )
Catalog #
For fixtures w/120V
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 106
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 111
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
109
Micro-Flood–Wide
Lamp
Included!
NSW Series Order Information
NSW Series
Yoke Mount
Candlepower Trace through origin
400W MH Micro Flood-Wide
NEMA Type 7H x 6V.
.3
.5
1
3
5
0 6. 1 1 2 .2
12 .2
1 8. 3
2 4 .4
24 .4
6. 1
1 8 .3
0 20’ 40 ’
4 0’ 2 0’
6 0’
80 ’
60 ’
8 0’
1 2. 2
0 m
6 .1
1 2. 2
1 8. 3
6 .1
20 ’
0 ’
20 ’
40 ’
60 ’
40 ’
Isofootcandle plot of 400W MH
Micro Flood- Wide at 25' (7.6 m)
Mounting height, and 20° tilt
above horizontal.
12.8" (325 mm)
14.0" (356 mm)
6.0" (152 mm)
www.ruudlighting.com
pg_0009
NPPG
110
Micro Flood
Lamp
Included!
NS Series Order Information
Micro Flood Housing
The seamless, die-cast aluminum
housing is standard with our exclusive
DeltaGuard
®
finish, featuring an E-coat
epoxy primer with bronze ultra-durable
powder topcoat. Consult factory for
availability of other finish colors.
Lens
A high impact, clear tempered and
annealed glass lens is secured in a die-
cast aluminum door frame.
Optics
A diffuse reflector is designed to provide
conventional floodlighting for a variety
of surfaces and areas. The new axial
parabolic version features medium or
narrow beam distribution for
applications where more precise control
is desired.
Ballast
50, 70 and 100W MH and 50 and 70W
HPS fixtures are standard with a normal
power factor, Dual-volt ballast
(120/277V). 35, 50, 70, 100 and 150W
HPS and 100W MV are standard with
120V npf ballast. Flourescent fixtures
are standard with an electronic universal
ballast that senses supply voltage 120
through 277-volt. See order chart for
other ballast options.
Lamps
The Micro Flood accommodates
medium base 50, 70 or 100W MH, 35,
50, 70, 100 or 150W HPS, 70 or 100W
G12 MH, or 100W MV. Fluorescent
fixtures are standard with a 13 or 26W
twin (quad) tube, 32 or 42W triple tube
compact fluorescent lamp.
Gasketing
Complete silicone gasketing at lens and
mounting provides a watertight seal.
Mounting
A 1/2" NPSM threaded fitter end is
standard.
Labels
UL Listed in the US and Canada for wet
locations and enclosure classified IP54
per IEC 529 and IEC 598.
Add note to dimensional drawing:
Add 0.88"D to Axial Parabolic models.
Isofootcandle plot of 13W fluorescent
Micro Flood at 10' (3.0 m) mounting
height, with 0° vertical tilt (plan view).
Isofootcandle plot of 150W HPS Micro
Flood at 20' (6.1 m) mounting height,
with 60° vertical tilt (plan view).
4.75"
(121 mm)
6.25"
(159 mm)
9.75"
(248 mm)
15 '
10 '
0 '
5'
15 ' 10'
5'
0'
1 5'
1 0'
5'
5'
1 0'
1 5'
1 .5
1
.5
.3
.1
4. 6
3. 0
0 m
1. 5
4. 6 3 .0
1. 5
0 m
4 .6
3 .0
1 .5
1 .5
3 .0
4 .6
0 ' 10'
10' 20 '
2 0'
3 0'
30 '
0'
1 0'
2 0'
3 0'
4 0'
5 0'
6 0'
1 0'
7 0'
4 0'
4 0'
5
3
2
1
. 5
. 3
0 m 3. 0
3 .0 3. 7
3 .7
9. 2
9. 2
0 m
3. 0
3. 7
9. 2
12. 2
15. 3
18. 3
3. 0
2 1. 4
12 .2
12. 2
Back view of NS Series with supplied
1/2" Adjustable Fitter Mount.
Lamp Type Wattage/Voltage Catalog Number
HID
50W MH, 120/277V NS6405-D
70W MH, 120/277V NS6407-D
100W MH, 120/277V NS6410-D
35W HPS, 120V
NS6503-1
50W HPS, 120V
NS6505-1
50W HPS, 120/277V NS6505-D
70W HPS, 120V
NS6507-1
70W HPS, 120/277V NS6507-D
100W HPS, 120V
NS6510-1
150W HPS, 120V
NS6515-1
100W MV, 120V
NS6310-1
Fluorescent 13W Fluorescent
NS6213-UL
26W Fluorescent
NS6226-UL
32W Fluorescent
NS6232-UL
42W Fluorescent
NS6242-UL
Axial Parabolic 70W MH* 120/277V NSM6407-D
Medium
100W MH* 120/277V NSM6410-D
Axial Parabolic 70W MH* 120/277V NSN6407-D
Narrow
100W MH* 120/277V NSN6410-D
*G12 tubular lamp
NOTE: All Micro Floods are supplied with the 1/2" Adjustable Fitter Mounting
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
HID High Power Factor
H
Magnetic ballast Normal Power Factor
(1) 13W lamp 120V
1
(1) 13W lamp 277V
2
(2) 13W lamp (26W) 120V
1
(2) 13W lamp (26W) 277V
2
Magnetic ballast High Power Factor
(1) 13W lamp 120V
H
(1) 13W lamp 277V
H
(2) 13W lamp (26W) 120V
H
(2) 13W lamp (26W) 277V
H
Tri-volt ballast (70 & 100W MH and 70W HPS only) T
(Canada only)
Photocell
(120V, 277V or 347V)
1, 2 or 6 P or LP
(P= Magnetic Ballast, LP= Electronic Ballast)
Tamperproof Lens Fasteners
J
Linear spread lens– horizontal
X
Linear spread lens– vertical
Y
Accessories: (Field-installed)
Description
Catalog Number
Color Filter (Axial Parabolic models only) NS-AF*
*specify color; A = Amber, B =Blue, G = Green, R = Red
Deep Baffle
DB-9
Wire Guard
FWG-9
Glare Shield
GS-9
Mounting Box
MNB-1
Mounting Box with Stake, Cord & Plug
MNB-2
Conduit Slipfitter
MNH-2
Ground Mount Post
PGM-1
Tamperproof Screwdriver
TPS-1
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 106
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 111
Add 0.88"D to Axial Parabolic models.
Standard HID
Axial Parabolic
HID
Fluorescent
NPPG 110
www.ruudlighting.com
pg_0010
NPPG 111
NPPG 111
External Photocell
This photocell is factory-installed and
must be ordered at the same time as
the fixture. It measures 3-3/8"L x 2"W x
1-1/2"H. An adjustable window slide
allows setting of early turn off/on. See
product pages for pricing and catalog
numbers.
Micro Flood Accessories
111
Ground Mount
Post
Catalog #PGM-1
Use with 2" Adjustable Fitter for ground
mounted floodlight fixtures. Wiring or
conduit feeds through post base.
Overall: 24"H (610 mm).
Tube: 18"H x 2.4"D (457 x 60 mm).
Base: 4.9"W x 6.3"L (124 x 159 mm).
Deep Baffle
Catalog #DB-9
For use with NS, NSM and NSN Series.
The aluminum baffle controls light
direction and provides full side cutoff. It
simply wraps around lens frame and is
secured with two supplied fasteners.
Standard with our exclusive DeltaGuard
finish, featuring an E-coat epoxy primer
with bronze ultra-durable powder
topcoat. Consult factory for availability
of other finish colors.
Wire Guard
Catalog #FWG-9
For use with NS, NSM and NSN Series.
The steel Wire Guard provides
protection in high vandalism areas. It
attaches to the lens with supplied #8-32
black stainless steel screws. A black
acrylic E-coat finish is standard. Size is
9.64" x 6.13" x 1.46". 1" between wires.
Mounting Box
Catalog #MNB-1
For use with NS, NSM and NSN Series.
The cast aluminum box measures 2.5" x
2.5" x 3.75" W, and provides an
enclosed wiring chamber to mount a
fixture with the 1/2" Adjustable Fitter.
Four threaded knockouts are provided
for 1/2" conduit entry, one on the top,
back and on either side. Standard with
our exclusive DeltaGuard finish,
featuring an E-coat epoxy primer with
bronze ultra-durable powder topcoat.
Consult factory for availability of other
finish colors.
Mounting Box
with Stake, Cord & Plug
Catalog #MNB-2
For use with NS, NSM and NSN Series.
This is the same construction as the
MNB-1 Mounting Box, but with a 6.5"
long aluminum stake for mounting into
the ground. A gasketed, 10 ft. cord is
supplied with a 120V straight blade
plug. Standard with our exclusive
DeltaGuard finish, featuring an E-coat
epoxy primer with bronze ultra-durable
powder topcoat. Consult factory for
availability of other finish colors.
Conduit Slipfitter
Catalog #MNH-2
For use with NS, NSM and NSN Series.
The cast aluminum hub provides a
threaded entry for the 1/2" Adjustable
Fitter, and slips over a 2-3/8" O.D. pipe
or tenon. A 3/8" allen set screw is
provided to secure the slipfitter.
Standard with our exclusive DeltaGuard
finish, featuring an E-coat epoxy primer
with bronze ultra-durable powder
topcoat. Consult factory for availability
of other finish colors.
Glare Shield
Catalog #GS-9
For use with NS, NSM and NSN Series.
The aluminum glare shield holds
forward brightness to a minimum for
eye-level fixtures. It simply wraps
around lens frame and is secured with
two supplied fasteners. Standard with
our exclusive DeltaGuard finish,
featuring an E-coat epoxy primer with
bronze ultra-durable powder topcoat.
Consult factory for availability of other
finish colors.
Button Photocell
This photocell is suitable for any
outdoor fixture with a 120, 208, 240,
277, and 347V ballast. A knockout is
provided in the 2" Adjustable Fitter to
field-install the button-type photocell.
There is no sensitivity adjustment. See
product pages for pricing and catalog
numbers.
Wire Guard
Catalog #
FWG-14
For NSF, NSC, and NSW Series.
Steel guard provides protection to
optical system. Attaches easily around
lens frame with supplied #8 stainless
steel screws. A black acrylic E-coat
finish is standard.
Deep Baffle
Catalog # Depth
DB-14 5.375"
For NSF and NSC Series.
Aluminum baffle allows precise control
of light direction while maintaining full
side cutoff. Attaches to lens frame with
supplied #8 fasteners. Finished in black
ultra-durable powder topcoat.
Glare Shield
Catalog # Depth
GS-14 5.375"
For NSF, and NSW Series.
The aluminum glare shield holds
forward brightness to a minimum for
eye-level fixtures. It attaches easily
around lens frame with two supplied
fasteners. Finished in black ultra-
durable powder topcoat.
www.ruudlighting.com
pg_0011
NPPG 112
Sq
u
are Series
The Square Series is available
with 14 different optical
systems, designed to satisfy
almost any lighting job. These
high-performance fixtures have
computer-designed optics that
produce precise light
distribution as well as glare
control.
Floodlight Optical Systems
This product group is
characterized by its ability to be
tilted above horizontal, which
allows placement of the main
beam in the optimum position
for the project. This group
includes: Standard, Cutoff,
Parabolic Medium and Narrow
and Narrow Beam Cutoff.
Several mountings are offered
for projects that require the
fixture’s aiming angle to be
adjusted. Refer to the
mountings on page 114 and the
mounting brackets shown on
pages 150 and 151.
Area Light Optical Systems
These lights are typically used
at a fixed position, parallel to
the ground. Their optical
systems are designed to place
the main beam in the correct
position without any tilt angle.
This group includes: Vertical
Forward Throw, Parking/
Roadway, Area Cutoff and
Quadrate Vertical and
Horizontal. Several mountings
are offered; please see page
114 for mountings and pages
150 and 151 for mounting
brackets.
112
Capacitor, starter and other electrical
components are strategically located and
heat sunk to the housing to increase life
Internal ribbing structure to prevent
any wall distortion or sagging
4kv-rated porcelain lamp socket
Aluminum die-cast housing
HID lamp supplied with fixture
Precise reflector systems using various high
efficiency pre-finished reflector sheets for
optimized lighting results
Constant-wattage, high-power-factor ballast
assembly is heat sunk to the aluminum
housing for increased life
Ballast compartment cover restricts access
during relamping, providing added safety
Patented internal hinge assembly
Aluminum die-cast door frame
Tempered-glass lens for
maximum impact resistance
Black stainless-steel
captive fasteners
Silicone gasket to assure a lifetime seal
DeltaGuard
®
finish, featuring E-coat
epoxy primer and bronze ultra-
durable powder topcoat
Square Steel and aluminum poles available (DeltaGuard finish to match fixtures)
22"
16"
12"
12" square x 5" deep (305 x 127 mm)
16" square x 6.5" deep (406 x 165 mm)
22" square x 9.25" deep (559 x 235 mm)
CF Series
Typical Cutaway
www.ruudlighting.com
pg_0012
NPPG 113
113
Installation Simplified
Your efforts installing these fixtures are
reduced because of four primary design
considerations. The first is that all
fixtures come complete with the lamp
already inside the fixture. This
eliminates the coordination of lamp
shipment and assures you that the right
lamp is provided. The second design
feature is that most fixtures come with
a quad-volt ballast of common local
voltages. The third is simplicity of
mounting designs. For example, with
the 2-inch Adjustable Fitter, just two set
screws are needed. And they face you,
rather than being located on all four
sides of the fitter. The fourth feature is
the patented "internal" hinging system
that automatically positions the lens
assembly when it is closed. This
requires only two stainless-steel
screws to secure the lens assembly.
Less Wind Loading
Computer-designed optics, using
compact lamps and superior heat-
dissipation techniques, allow the
compact size of our square housings.
Size and shape reduce wind load,
resulting in cost savings when
determining pole specifications.
Fourteen Reflector Options
Fourteen reflector systems provide the
flexibility to accomplish any lighting
task in the most optimized manner.
Our engineers use the latest computer-
design techniques for reflector systems
that provide optimum results. This has
resulted in our using smaller envelope
lamps in some reflectors to achieve the
desired optimized results. For example,
our AC Series Forward Throw fixture
could not have been achieved without
being double its size. However, by using
the ED28 reduced-envelope lamp for the
400-watt metal halide and the BT37
reduced-envelope lamp for the 1000-
watt MH, we were able to develop
optical systems that have a forward
main beam at 60+ degrees with no
fixture tilt and virtually no back light.
This amazing reflector system allows
you to illuminate parking lots and tennis
courts with minimal spill light onto
adjacent properties. The reflector system
and adjustable backlight cutoff also
allow direct or indirect wall-mounted
lighting without the typical
objectionable wall brightness.
Longer Fixture Life
All products are standard with our
exclusive DeltaGuard
®
finish, featuring
an E-coat epoxy primer and a bronze
ultra-durable powder topcoat. The ultra-
durable finish is resistant to the
degrading effects of the ultraviolet
radiation from the sun and other
environmental factors. This assures you
that the products you install today will
look great in the future. We also offer a
seven-year finish warranty.
Lamps
12-inch housings and 175-watt MH and
150-watt HPS accommodate medium-
base lamps. MAM and MAN series also
available with G12 tubular lamp.
16-inch housings accommodate
mogul-base lamps (the PM, PN and the
AC Series use an ED28 reduced-
envelope lamp for 400-watt MH
fixtures). 22-inch housings
accommodate mogul-base lamps (the
QV Square Tube Post Top and VFT
Series use an ED28 reduced-envelope
lamp for 400-watt PSMH and 400-watt
MH fixtures; the PM, PN, AC, VFT and
QV Square Tube Post Top Series use a
BT37 reduced-envelope lamp for 1000-
watt PSMH and 1000-watt MH fixtures.
All 320-watt PSMH fixtures use the
ED28 reduced envelope lamp.
Weather-tight housing
The aluminum housing is manufactured
with the latest die-casting technology.
This unique styling allows straight wall
sections. The die-cast doorframe has a
high-temperature silicone gasket and
high-impact, strength-tempered glass
lens. The lens frame is supplied with
mounting holes for field-installed
accessories. For the VFT Series, a clear
sag lens (acrylic on 250-400 watts and
glass on 750- and 1000-watt PSMH and
1000-watt MH) is used and lens frame
is supplied with mounting clips for the
Backlight Shield accessory. For the
Square Tube Post Top, all horizontal
lamps and 50-175-watt vertical lamps
are supplied with a clear, flat, tempered-
glass lens; 250-1000-watt vertical
lamps have a sag tempered-glass lens.
Structural Integrity
Internal ribbing is designed into the
housing to distribute structural loads.
This allows the fixture to be mounted in
any operating position without any wall
distortion. Typical fixture leaks are
eliminated. The internal structure also
prevents fatigue failure of the housing.
Ballasts
All fixtures are standard with a high
power factor ballast. The majority of
Flood/Area fixtures are supplied with
a multi-volt ballast. In the US, the
standard ballast includes 120, 208, 240
and 277 volts; in Canada, the standard
ballast includes 120, 277 and 347 volts
(some wattages are standard with a
120/277 dual-volt ballast).
Wiring
150°C minimum supply wire is required
for wall-mounted fixtures.
Labels
UL Listed in US and Canada for wet
locations, and enclosure classified IP54
and/or IP65 per IEC 529 and IEC 598.
Square Series Catalog Number Logic
NOTE: See product pages for availability.
M
CF
3
6
15
M
M = 12" “Mini" Housing
(blank) = 16" or 22" square housing
according to wattage
Lamps/Ballasts
4 = Metal Halide
5 = High Pressure Sodium
6 = Pulse Start Metal Halide
7 = G12 Ceramic Metal Halide
Wattages
03 = 35W HPS
05 = 50W
07 = 70W
10 = 100W
15 = 150W
17 = 175W MH
25 = 250W
32 = 320W PSMH
40 = 400W
75 = 750W PSMH
92 = 250W (22" housing)
94 = 400W (22" housing)
99 = 1000W (22" housing)
95 = 1500W MH (22" housing)
925 = 250W PSMH (22" housing)
932 = 320W PSMH (22" housing)
940 = 400W PSMH (22" housing)
Other lamp wattages available-
consult factory
Voltages
27= 277V Reactor Ballast
(150–400W PSMH)
1 = 120V
2 = 277V
3 = 208V
4 = 240V
5 = 480V
6 = 347V (Canada only)
D = Dual-volt (120/277V)
M = Quad-volt (120/208/240/277V)
T = Tri-volt (120/277/347V)
(Canada only)
NOTE: D, M or T voltage suffix are
factory set at highest voltage.
Optical Systems
AC = Area Cutoff (pg. 122)
AM = Axial Medium Parabolic (pg. 120)
AN = Axial Narrow Parabolic (pg. 120)
CF = Cutoff Flood (pg. 116)
CN = Narrow Beam Cutoff (pg. 117)
FS = Standard Flood (pg. 115)
PM = Parabolic Medium (pg. 118)
PN = Parabolic Narrow (pg. 119)
PR = Parking/Roadway (pg. 124)
QV = Quadrate Vertical (pg. 126–127)
QH = Quadrate Horizontal (pg. 126–127)
VFT = Vertical Forward Throw (pg. 123)
VPR= Vertical Parking/ Roadway (pg. 125)
W = Sign Light (pg. 121)
Mountings
0 = Direct
1 = 1-1/2" Close Pole
2 = 6" Extended Pole
3 = 2" Adjustable Fitter
4 = Yoke
5 = 20° Fixed
6 = 1/2" Adjustable Fitter
(12" housing)
8 = Without Mounting (hardware)
(factory-drilled)
A = Square Tube Center Tenon
C = Square Tube 4" Center Direct
(for 4" pole)
D = Square Tube 5" Center Direct
(for 5" pole)
E = Square Tube 6" Center Direct
(for 6" pole)
F = Round Tube Center Tenon
H = Round Tube Center Direct
K = Round Tube Off-Center Tenon
M = Round Tube Off-Center Direct
U = Indirect Wall (uplight)
W = Wall (includes wall mount box)
www.ruudlighting.com
pg_0013
NPPG 114
NPPG 114
114
Square Series Mountings
1-1/2" Close Pole Mount
Mounting Code “1"
• For AC, PR, QV, VFT and VPR Series.
• Extruded aluminum mounting arm
attaches fixture in a fixed horizontal
position to the side of a square pole.
A steel backing plate inside the pole
secures the fixture.
• On 12" housings, the arm measures
1-1/2" L x 2-1/2" H; on 16" and 22"
housings, it measures 1-1/2" L x
4-1/2" H.
6" Extended Pole Mount
Mounting Code “2"
• For AC, PR, QV, VFT and VPR Series.
• Extruded aluminum mounting arm
attaches fixture in a fixed horizontal
position to the side of a square pole.
A steel backing plate inside the pole
secures the fixture.
• On 12" housings, the arm measures
6" L x 2-1/2" H; on 16" and 22"
housings, the arm measures
6" L x 4-1/2" H.
2" Adjustable Fitter
Mounting Code “3"
• For AC, MAM, MAN, CF, CN, FS, PM,
PN, PR and W Series.
• Slip-fits over a 2" pole or tenon
(2-3/8" O.D.).
• Allows tilt above horizontal in 2-1/2°
increments, as well as lateral rotation.
• Provides enclosed and gasketed
internal wiring chamber.
• Knockout provided for field-installed
photocell accessory.
Yoke Mount
Mounting Code “4"
• For AC, MAM, MAN, CF, CN, FS, PM,
PN, PR and W Series.
• Ideal for wall, ground, roof or wood
pole mounting; bolts directly to
almost any surface.
• Provided with 36" external cord for
ease of wiring.
• Allows tilt above horizontal to any
angle, and double locks in 5°
increments.
20° Fixed Mount
Mounting Code “5"
• For CF Series only.
• Provides optimum tilt above
horizontal angle for cutoff optics,
where adjustability is not required.
• Arm bolts directly to side of square
pole; backing plate secures arm
inside pole.
1/2" Adjustable Fitter
Mounting Code “6"
• For 12" AC, MAM, MAN, CF, FS, PM,
PN, and PR Series.
• NPSM threaded end for mounting to
1/2" threaded pipe or junction box.
• Allows tilt above horizontal in 5°
increments.
Round Tube Center Direct
Mounting Code: “H"
Round Tube Center Tenon
Mounting Code: “F"
• For 16" QV and QH Series only.
• Fabricated aluminum yoke comprised
of round extruded arms and base (H)
or cast hub (F) supports fixture
housing directly over pole.
• Base (H) fits inside a 4" square pole,
and is secured with four 5/16-18 steel
screws.
• Hub (F) slip-fits over a steel or
aluminum tenon or pole measuring
2-3/8" up to 3" O.D., and is secured
with eight allen head set screws to
prevent rotation.
Square Tube Center Direct
Mounting Code: 4" Pole=“C";
5" Pole=“D"; 6" Pole=“E"
Square Tube Center Tenon
Mounting Code: “A"
• For QV and QH Series only.
• Fabricated aluminum yoke comprised
of square extruded arms and base (C,
D or E) or cast hub (A) supports
fixture housing directly over pole.
• Base (C, D or E) fits inside a 4", 5" or
6" square pole, secured with four
5/16-18 steel screws.
(5" or 6" base available with 22"
square housing only).
• Mounting hub (A) is secured with
eight allen head set screws (supplied)
to prevent rotation. The hub slip-fits
over a steel or aluminum tenon
measuring 2-3/8" (standard) up to 3"
O.D. When mounting 22" square
fixtures on fiberglass or aluminum
poles, a 3" O.D. steel tenon that
mounts inside the pole is required.
Wall Mount
Mounting Code “W"
• For AC, PR and VFT and VPR Series.
• Cast aluminum mounting box with
gasket attaches in a fixed position to
the side of fixture, utilizing threaded
mounting studs supplied.
• Provided with 4 threaded and closed
1/2" conduit entries.
• 150°C minimum supply wire is
required.
Round Tube Off-Center Direct
Mounting Code “M"
Round Tube Off-Center Tenon
Mounting Code “K"
• For 16" AC and PR Series only.
• Fabricated aluminum yoke comprised
of round extruded arms and base (M)
or cast hub (K) supports fixture
housing off-center of pole.
• Base (M) fits inside a 4" square pole,
and is secured with four 5/16-18 steel
screws.
• Hub (K) slip-fits over a steel tenon or
pole measuring 2-3/8" up to 3" O.D.;
secured with eight allen head set
screws to prevent rotation.
M
K
C, D or E
H
Supplied Wall
Mount Box
F
A
www.ruudlighting.com
pg_0014
NPPG 115
NPPG 115
115
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
12" 150W PSMH MFS
*
615-M
3
= 2" Adjustable Fitter
1 6" 320W PSMH FS
*
632-M
4
= Yoke Mount
12" 50W MH MFS
*
405-D
6
= 1/2" Adjustable Fitter
12" 70W MH MFS
*
407-D (
1/2" Adj. Fitter for use on 12" housing only)
12" 100W MH MFS
*
410-D
8
= Without Mounting (hardware)
12" 175W MH MFS
*
417-M (factory-drilled)
16" 175W MH FS
*
417-M
16" 250W MH FS
*
425-M
16" 400W MH FS
*
440-M
22" 1000W MH FS
*
499-M
22" † 1500W MH FS
*
495-M
12" 35W HPS MFS
*
503-1
12" 50W HPS MFS
*
505-D
12" 70W HPS MFS
*
507-M
12" 100W HPS MFS
*
510-M
12" 150W HPS MFS
*
515-M
16" 250W HPS FS
*
525-M
16" 400W HPS FS
*
540-M
22" 1000W HPS FS
*
599-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH
† 1500W MH fixture must be positioned with a minimum 30° tilt above horizontal.
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( PS M H onl y)
27
120V Reactor ballast (50–150W HPS 12" housing only) 1
480V ballast
( 320W PS M H, 175–1500W M H & 70–1 000W H PS on ly )
5
Quad-volt ballast (50–100W MH only)
M
Tri-volt ballast (320W PSMH,
T
70–1500W MH & 70–1000W HPS only) (Canada only)
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
(delay-relay type) (includes 100W Q lamp)
Q
NOTE: Not available for 1500W or 277V Reactor
Uplight Lens Frame
U
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter)
NOTE: n/a on 1000W w/120V; all 1500W; all 480V
27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (page 131)
For fixtures w/1000W, 120V
1 P
For fixtures w/480V
5 P
For fixtures w/1500W
1, 2, 3, 4, 5 or 6 P
Accessories: (Field-installed)
12" housing 16" housing 22" housing
Deep Baffle DB-12
DB-16
DB-22
Wire Guard FWG-12
FWG-16
FWG-22
Glare Shield GS-12
GS-16
GS-22
Polycarbonate Vandal Shield (n/a on 1500W or if fixture is used in an uplight position)
LS-12
LS-16
LS-22
Button Photocell
( Fi el d-i nst a ll ed in fi x tur e s w it h 2" Ad jus ta bl e Fit te r )
Catalog #
For fixtures w/120V (n/a on 1000W)
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
A general-purpose floodlight, the FS Series is typically installed with a 45° to 60° tilt
above horizontal to provide a wide coverage of illumination. This fixture is ideal for
lighting signs, large open areas and facades. The optical chamber is sealed to reduce
dirt and insect contamination.
Three Sizes:
12" square x 5" deep (305 x 127 mm)
16" square x 6.5" deep (406 x 165 mm)
22" square x 9.25" deep (559 x 235 mm)
Standard Floodlight
Lamp
Included!
FS Series Order Information
2 000
4 000
6 000
8 000
1 0000
12 000
14 000
16 000
18 000
20 000
22 000
24 000
72 54 36 1 8 0
A NGLE ( IN DE GRE E S )
18 36 54 7 2
V e rt ic a l
H o ri zo n t al
40'
20'
0'
20 '
40'
60'
80'
100'
120'
140'
160'
40'
6 0'
80'
100' 2 0' 0' 20' 40 ' 60' 8 0' 10 0'
5
3
2
1
. 5
. 3
. 1
12 .2
6 .1
0 m
6.1
12 .2
18 .3
24. ,4
30 .5
36 .6
42 .7
48 .8
1 2 .2
1 8. 3
2 4 .4
30 . 5 6 .1 0 m 6 .1 12 .2 1 8 .3 2 4. 4 3 0 .5
Candlepower Trace through origin
400W HPS Standard Floodlight
NEMA Type 7H x 6V.
Isofootcandle plot of 400W HPS
Standard Floodlight at 30' (9.1 m)
mounting height with 60° tilt above
horizontal.
5000
10000
15000
20000
25000
30000
35000
40000
45000
50000
55000
60000
72 5 4 36 18 0
A NG LE ( IN DE GRE E S )
18 3 6 54 72
V er t ica l
H o riz on t a l
3 0'
0'
3 0'
6 0'
9 0'
12 0'
15 0'
18 0'
21 0'
24 0'
27 0'
60 '
90'
1 20'
150 ' 30' 0' 30' 60' 90 ' 12 0' 1 50'
10
5
3
2
1
.5
.3
.1
9. 2
0 m
9. 2
18. 3
27. 5
42. 7
45. 8
54. 9
64. 0
73. 2
82. 4
1 8. 3
2 7 .5
4 2. 7
4 5 .8 9 .2 0 m 9 .2 1 8 .3 2 7. 5 4 2 .7 4 5. 8
Candlepower Trace through origin
1000W HPS Standard Floodlight
NEMA Type 7H x 6V.
Isofootcandle plot of 1000W HPS
Standard Floodlight at 40' (12.2 m)
mounting height with 60° tilt above
horizontal.
FS Series
2" Adjustable Fitter
www.ruudlighting.com
pg_0015
NPPG 116
NPPG 116
116
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
12" 150W PSMH MCF
*
615-M
3
= 2" Adjustable Fitter
16" 320W PSMH CF
*
632-M
4
= Yoke Mount
22" 750W PSMH CF
*
675-M
5
= Fixed 20° Mount
12" 50W MH MCF
*
405-D
6
= 1/2" Adjustable Fitter
12" 70W MH MCF
*
407-D (
1/2" Adj. Fitter for use on 12" housing only)
12" 100W MH MCF
*
410-D
8
= Without Mounting (hardware)
12" 175W MH MCF
*
417-M (factory-drilled)
16" 175W MH CF
*
417-M
16" 250W MH CF
*
425-M
16" 400W MH CF
*
440-M
22" 1000W MH CF
*
499-M
12" 35W HPS MCF
*
503-1
12" 50W HPS MCF
*
505-D
12" 70W HPS MCF
*
507-M
12" 100W HPS MCF
*
510-M
12" 150W HPS MCF
*
515-M
16" 250W HPS CF
*
525-M
16" 400W HPS CF
*
540-M
22" 1000W HPS CF
*
599-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( P SM H o nly )
27
120V Reactor ballast (50–150W HPS 12" housing only) 1
480V ballast
(32 0W P SM H , 175–1 000W M H & 70– 1000W HP S only )
5
Quad-volt ballast (50–100W MH only)
M
Tri-volt ballast (320W PSMH,
T
70–1500W MH & 70–1000W HPS only) (Canada only)
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
(delay-relay type) (includes 100W Q lamp) (n/a 277V Reactor)
Q
Uplight Lens Frame
U
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter )
NOTE: n/a on 1000W w/120V; all 480V 27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 131)
For fixtures w/1000W, 120V
1 P
For fixtures w/480V
5 P
Accessories: (Field-installed)
12" housing 16" housing 22" housing
Wire Guard FWG-12
FWG-16
FWG-22
Backlight Shield SBL-12
SBL-16
SBL-22
Polycarbonate (n/a if fixture is used in an uplight position)
Vandal Shield LS-12
LS-16
LS-22
Button Photocell
( Fi e ld-i ns ta ll e d i n f ix tur e s w i th 2" A djus t abl e Fi tt er )
Catalog #
For fixtures w/120V (n/a on 1000W)
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
This cutoff luminaire has an optical system specifically designed to assure maximum
main beam projection, while minimizing spill light. It is generally positioned with a
15° to 25° tilt above horizontal to reduce glare and obtain optimum performance.
The CF Series can be used for parking lots, auto sales lots and outdoor sports areas
(volleyball, tennis courts, etc.).
Three Sizes:
12" square x 5" deep (305 x 127 mm)
16" square x 6.5" deep (406 x 165 mm)
22" square x 9.25" deep (559 x 235 mm)
Cutoff Floodlight
Lamp
Included!
CF Series Order Information
CF Series
2" Adjustable Fitter
Adjustable
Backlight
Cutoff
Perpendicular
to Fixture
50
°
The main beam is 50° above a line
perpendicular to the face of the fixture.
18 0
°
1 50
°
120
°
9 0
°
6 0
°
20000
30
°
0
°
40000
40 '
0'
20 '
4 0'
60'
8 0'
40'
6 0'
80' 0' 2 0' 60' 8 0'
1 20'
20 '
1 00'
2 0' 40'
1 40'
16 0'
10 0'
100 '
1 2.2
0 m
6.1
12. 2
18. 3
24. 4
1 2 .2
1 8 .3
2 4 .4 0 m 6 .1 1 8 . 3 24 . 4
36. 6
6.1
30. 5
6 . 1 1 2 .2
42. 7
48. 8
3 0 .5
3 0 .5
.1
1
3
5
.5
.3
Candlepower Distribution Curve of
400W HPS Cutoff Floodlight, 20° tilt
above horizontal.
Isofootcandle plot of one 400W HPS
Cutoff Floodlight at 30' (9.1 m) mounting
height, and 20° tilt above horizontal.
1 20
°
90
°
60
°
100000
30
°
200000
20'
0'
20'
40'
60'
80'
100'
120'
140'
160'
180'
40'
6 0'
80'
100' 2 0' 0' 20' 40 ' 60' 8 0' 10 0'
1 0
5
3
1
.5
.3
6. 1
0 m
6. 1
12. 2
1 8. 3
2 4. 4
3 0. 5
3 6. 6
4 2. 7
4 8. 8
5 4. 9
1 2 .2
1 8 .3
2 4 .4
3 0 .5 6 . 1 0 m 6. 1 1 2 .2 1 8 .3 2 4 .4 3 0 .5
Candlepower Distribution Curve of
1000W HPS Cutoff Floodlight, 20° tilt
above horizontal.
Isofootcandle plot of one 1000W HPS
Cutoff Floodlight at 40' (12.2 m)
mounting height, and 20° tilt above
horizontal.
www.ruudlighting.com
pg_0016
NPPG 117
NPPG 117
117
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
2 2" 320W PSMH CN
*
6932-M
3
= 2" Adjustable Fitter
22" 400W MH CN
*
494-M
4
= Yoke Mount
22" 1000W MH CN
*
499-M
8
= Without Mounting (hardware)
22" † 1500W MH CN
*
495-M
(factory-drilled)
22" 400W HPS CN
*
594-M
22" 1000W HPS CN
*
599-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH
† 1500W MH fixture must be positioned with a minimum 30° tilt above horizontal.
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
(P SM H only )
27
480V ballast
5
Tri-volt ballast (Canada only)
T
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
(delay-relay type) (includes 100W Q lamp) (n/a 277V Reactor)
Q
Button Photocell
( Fac to r y- ins ta ll e d w i th Yoke M ount)
27, 1, 2, 3, 4 or 6 P
NOTE: n/a on 1000W w/120V; all 1500W; all 480V
External Photocell (Factory-installed) (Page 131)
For fixtures w/1000W, 120V
1 P
For fixtures w/480V
5 P
For fixtures w/1500W
1, 2, 3, 4, 5 or 6 P
Accessories (Field-installed)
Description
Catalog #
Polycarbonate Vandal Shield
LS-22
(n/a on 1500W or if fixture is used in an uplight position)
Button Photocell (Field-installed in fixtures with 2" Adjustable Fitter)
For fixtures w/120V (n/a on 1000W)
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
The Narrow Beam Cutoff Floodlight provides narrow vertical and wide horizontal
distribution. For the 1500-watt MH fixture, a minimum 30° tilt above horizontal is
required. The 2-inch Adjustable Fitter for this wattage features a lock to prevent
mounting below this tilt angle. Ideal for lighting large sports fields, building facades
and signs.
One Size:
22" square x 9.25" deep (559 x 235 mm)
Narrow Beam Cutoff Floodlight
Lamp
Included!
CN Series Order Information
CN Series
2" Adjustable Fitter
Candlepower Trace through origin
1000W MH Narrow Beam Cutoff Flood.
NEMA Type 5H x 5V.
Isofootcandle plot of 1000W MH Narrow
Beam Cutoff Floodlight at 30' (9.1 m)
mounting height and 60° tilt above
horizontal.
1 0 0 0 0
2 0 0 0 0
3 0 0 0 0
4 0 0 0 0
5 0 0 0 0
6 0 0 0 0
7 0 0 0 0
8 0 0 0 0
9 0 0 0 0
1 0 0 0 00
1 1 0 0 00
1 2 0 0 00
4 8 3 6 2 4 1 2 0 1 2 2 4 3 6 4 8
V ER TIC AL
H O R IZO N TAL
AN G L ES ( IN D EG R EE S)
20'
0'
20'
40'
60'
80'
100'
120'
140'
160'
180'
6. 1
0m
6. 1
12. 2
18.3
24. 4
30. 5
36. 6
42. 7
48. 8
54. 9
0' 20' 40' 60' 80'100'
20'
40'
60'
80'
10 0'
0 m 6 .1 1 2.2 1 8 .3 2 4. 4 3 0.5
6.1
12 .2
18 .3
2 4.4
3 0 .5
.5
10
3
1
.3
.1
Candlepower Distribution Curve of
1000W HPS Narrow Beam Cutoff
Floodlight, 60° tilt above horizontal.
Isofootcandle plot of 1000W HPS
Narrow Beam Cutoff Floodlight at
30' (9.1 m) mounting height and 60°
tilt above horizontal.
3 0
°
6 0
°
1 2 0
°
1 5 0
°
3 0
°
6 0
°
1 2 0
°
9 0
°
9 0
°
1 5 0
°
1 0 0 0 0 0
2 0 0 0 0 0
3 0 0 0 0 0
20'
0'
20'
40'
60'
80'
100'
120'
140'
160'
180'
6. 1
0m
6. 1
12. 2
1 8.3
24. 4
30. 5
36. 6
42. 7
48. 8
54. 9
0' 20' 40' 60' 80' 100'
20'
40'
60'
80'
1 00'
0 m 6 .1 1 2.2 1 8 .3 24 .4 3 0. 5
6.1
12 .2
18 .3
2 4. 4
3 0. 5
.5
10
3
1
.3
.1
www.ruudlighting.com
pg_0017
NPPG 118
NPPG 118
The optics for the Medium Parabolic feature a smooth diffuse reflector providing a
medium distribution. The optical chamber is sealed to reduce dirt and insect
contamination. Ideal for illuminating tall, narrow subjects such as flagpoles, steeples,
columns and signs.
Three Sizes:
12" square x 5" deep (305 x 127 mm)
16" square x 6.5" deep (406 x 165 mm)
22" square x 9.25" deep (559 x 235 mm)
118
Medium Parabolic Floodlight
Lamp
Included!
PM Series Order Information
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
1 2" 150W PSMH MPM
*
615-M
3
= 2" Adjustable Fitter
1 6" 320W PSMH PM
*
632-M
4
= Yoke Mount
12" 50W MH MPM
*
405-D
6
= 1/2" Adjustable Fitter
12" 70W MH MPM
*
407-D (
1/2" Adj. Fitter for use on 12" housing only)
12" 100W MH MPM
*
410-D
8
= Without Mounting (hardware)
12" 175W MH MPM
*
417-M (factory-drilled)
16" 175W MH PM
*
417-M
16" 250W MH PM
*
425-M
16" 400W MH PM
*
440-M
22" 1000W MH PM
*
499-M
12" 35W HPS MPM
*
503-1
12" 50W HPS MPM
*
505-D
12" 70W HPS MPM
*
507-M
12" 100W HPS MPM
*
510-M
12" 150W HPS MPM
*
515-M
16" 250W HPS PM
*
525-M
16" 400W HPS PM
*
540-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH and 400W MH; BT37 for 1000W MH.
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( PS M H onl y )
27
120V Reactor ballast
( 50– 150W HP S 12" housi ng only )
1
480V ballast
( 320W PS M H, 175–1000W M H & 70–4 00W H PS onl y )
5
Quad-volt ballast (50–100W MH only)
M
Tri-volt ballast (320W PSMH,
T
70–1500W MH & 70–1000W HPS only) (Canada only)
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
( de la y -r e la y t ype ) ( i nc lude s 100W Q l am p) ( n/ a 277 V R e ac tor )
Q
Uplight Lens Frame
U
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter)
NOTE: n/a on 1000W w/120V; all 480V 27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 131)
For fixtures w/1000W, 120V
1 P
For fixtures w/480V
5 P
Linear spread lens– horizontal (12" housing only)
X
Linear spread lens– vertical (12" housing only)
Y
Accessories: (Field-installed)
12" housing 16" housing 22" housing
Deep Baffle DB-12
DB-16
DB-22
Wire Guard FWG-12
FWG-16
FWG-22
Polycarbonate Vandal Shield (n/a if fixture is used in an uplight position)
LS-12
LS-16
LS-22
Internal Louver DL-12
DL-16
not available
Button Photocell
( Fi el d-i nst a ll ed in fi x tur e s w it h 2" Ad jus ta bl e Fit te r )
Catalog #
For fixtures w/120V (n/a on 1000W)
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
PM Series
2" Adjustable Fitter
Candlepower Trace through origin
400W MH Medium Parabolic Floodlight
NEMA type 4H x 4V.
Isofootcandle plot of 400W MH Medium
Parabolic Floodlight at 30' (9.1 m)
mounting height and 60° tilt above
horizontal.
1 0 0 0 0
2 0 0 0 0
3 0 0 0 0
4 0 0 0 0
5 0 0 0 0
6 0 0 0 0
7 0 0 0 0
8 0 0 0 0
9 0 0 0 0
1 0 0 0 0 0
1 1 0 0 0 0
1 2 0 0 0 0
0
8
1 6
24
3 2
8 1 6 24 3 2
V ER TI CA L
H ORI ZON TA L
A NGL E (I N D EG RE ES )
18 0'
16 0'
14 0'
12 0'
10 0'
8 0'
6 0'
40'
2 0'
0'
2 0'
54. 9
48. 8
42. 7
36. 6
30. 5
24. 4
18. 3
12. 2
6. 1
0 m
6. 1
0' 20' 40' 6 0' 80 ' 10 0'
20'
40'
6 0'
80'
10 0'
0 m 6 .1 12 . 2 1 8 .3 2 4 .4 30 .5
6 .1
12 .2
1 8 .3
2 4 .4
30 .5
5
3
1
.5
.3
. 1
10
Candlepower Trace through origin
1000W MH Medium Parabolic Floodlight
NEMA type 3H x 4V.
Isofootcandle plot of 1000W MH
Medium Parabolic Floodlight at
40' (12.2m) mounting height and
0° tilt above horizontal.
2 0 0 0 0
4 0 0 0 0
6 0 0 0 0
8 0 0 0 0
1 0 0 0 0 0
1 2 0 0 0 0
1 4 0 0 0 0
1 6 0 0 0 0
1 8 0 0 0 0
2 0 0 0 0 0
2 2 0 0 0 0
2 4 0 0 0 0
0
1 0
20
3 0
40
1 0 2 0 3 0 4 0
V ER TI C A L
H OR IZ ONT A L
AN GL E (I N D EGR E ES )
100 '
80 '
60 '
40 '
20 '
0 '
20 '
40 '
60 '
80 '
100 '
30. 5
24. 4
18. 3
12. 2
6. 1
0 m
6. 1
12. 2
18. 3
24. 4
30. 5
0 ' 20' 4 0' 60 ' 80' 100 '
20 '
4 0'
60'
8 0'
100'
0 m 6 .1 1 2 .2 1 8. 3 24 .4 3 0 .5
6 .1
1 2 .2
18 .3
2 4 .4
3 0 .5
5
6 0
. 1
. 5
. 3
1
1 5
3
Shown with Internal Louver
Accessory
www.ruudlighting.com
pg_0018
NPPG 119
NPPG 119
The optics for the Narrow Parabolic feature a smooth, bright reflector, providing a
narrow distribution (approximately 20° on width and length). The optical chamber is
sealed to reduce dirt and insect contamination. Ideal for illuminating tall, narrow
subjects such as flagpoles, steeples, columns and signs.
Three Sizes:
12" square x 5" deep (305 x 127 mm)
16" square x 6.5" deep (406 x 165 mm)
22" square x 9.25" deep (559 x 235 mm)
119
Narrow Parabolic Floodlight
Lamp
Included!
PN Series Order Information
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
12" 150W PSMH MPN
*
615-M
3
= 2" Adjustable Fitter
16" 320W PSMH PN
*
632-M
4
= Yoke Mount
12" 50W MH MPN
*
405-D
6
= 1/2" Adjustable Fitter
12" 70W MH MPN
*
407-D (
1/2" Adj. Fitter for use on 12" housing only)
12" 100W MH MPN
*
410-D
8
= Without Mounting (hardware)
12" 175W MH MPN
*
417-M (factory-drilled)
16" 175W MH PN
*
417-M
16" 250W MH PN
*
425-M
16" 400W MH PN
*
440-M
22" 1000W MH PN
*
499-M
12" 35W HPS MPN
*
503-1
12" 50W HPS MPN
*
505-D
12" 70W HPS MPN
*
507-M
12" 100W HPS MPN
*
510-M
12" 150W HPS MPN
*
515-M
16" 250W HPS PN
*
525-M
16" 400W HPS PN
*
540-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH and 400W MH; BT37 for 1000W MH.
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( P SM H only )
27
120V Reactor ballast
( 50–150W H PS 12" hous ing only )
1
480V ballast
(32 0W P SM H , 175–1 000W M H & 70– 400W H P S only )
5
Quad-volt ballast (50–100W MH only)
M
Tri-volt ballast (320W PSMH,
T
70–1500W MH & 70–1000W HPS only) (Canada only)
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
( del ay -r e l ay t y pe) ( inc lude s 100 W Q l a mp) ( n/a 277V Re a ct or )
Q
Uplight Lens Frame
U
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter)
NOTE: n/a on 1000W w/120V; all 480V 27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 131)
For fixtures w/1000W, 120V
1 P
For fixtures w/480V
5 P
Linear spread lens– horizontal (12" housing only)
X
Linear spread lens– vertical (12" housing only)
Y
Accessories: (Field-installed)
12" housing 16" housing 22" housing
Deep Baffle DB-12
DB-16
DB-22
Wire Guard FWG-12
FWG-16
FWG-22
Polycarbonate Vandal Shield (n/a if fixture is used in an uplight position)
LS-12
LS-16
LS-22
Internal Louver DL-12
DL-16
not available
Button Photocell
( Fi e ld-i ns ta ll e d i n f ix tur e s w i th 2" A djus t abl e Fi tt er )
Catalog #
For fixtures w/120V (n/a on 1000W)
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
PN Series
2" Adjustable Fitter
Candlepower Trace through origin
400W MH Narrow Parabolic Floodlight
NEMA type 2H x 3V.
Isofootcandle plot of 400W MH Narrow
Parabolic Floodlight at 30' (9.1 m)
mounting height and 60° tilt above
horizontal.
2 0 0 0 0
4 0 0 0 0
6 0 0 0 0
8 0 0 0 0
1 0 0 0 0 0
1 2 0 0 0 0
1 4 0 0 0 0
1 6 0 0 0 0
1 8 0 0 0 0
2 0 0 0 0 0
2 2 0 0 0 0
2 4 0 0 0 0
0
6
1 2
1 8
2 4
6 1 2 1 8 24
V ER TI C AL
H OR IZON T AL
A N GLE ( I N D EGR E ES )
180'
160'
140'
120'
100'
80'
60'
40'
20'
0'
20'
5 4. 9
4 8. 8
4 2. 7
3 6. 6
3 0. 5
2 4. 4
1 8. 3
12. 2
6. 1
0 m
6. 1
0' 2 0' 40 ' 60' 80' 100'
20'
40 '
60'
80 '
1 00'
0 m 6 .1 1 2 .2 1 8 .3 2 4 .4 3 0 .5
6 .1
1 2. 2
1 8 .3
2 4. 4
3 0. 5
5
3
1
.5
.3
.1
10
20
Candlepower Trace through origin
1000W MH Narrow Parabolic Floodlight
NEMA type 2H x 4V.
Isofootcandle plot of 1000W MH Narrow
Parabolic Floodlight at 40' (12.2 m)
mounting height and 0° tilt above
horizontal.
50 0 0 0
1 00 0 0 0
1 50 0 0 0
2 00 0 0 0
2 50 0 0 0
3 00 0 0 0
3 50 0 0 0
4 00 0 0 0
4 50 0 0 0
5 00 0 0 0
5 50 0 0 0
6 00 0 0 0
0
8
1 6
2 4
3 2
8 1 6 2 4 3 2
VE RT IC A L
H OR I ZON TA L
A NG LE (I N D E GRE ES )
100 '
80 '
60 '
40 '
20 '
0 '
20 '
40 '
60 '
80 '
100 '
30. 5
24. 4
18. 3
12. 2
6. 1
0 m
6. 1
12. 2
18. 3
24. 4
30. 5
0 ' 20' 40' 60 ' 80' 100 '
20 '
4 0'
60'
8 0'
100 '
0 m 6 .1 1 2 .2 1 8 .3 24 . 4 3 0 .5
6 .1
1 2 .2
1 8. 3
2 4 .4
3 0 .5
5
60
.1
. 5
.3
1
1 5
20 0
3
Shown with Internal
Louver Accessory
www.ruudlighting.com
pg_0019
NPPG 120
NPPG 120
The optical system for Mini Axial Parabolic Medium has a smooth diffuse reflector
providing a symmetric 14-degree beam angle. The Mini Axial Parabolic Narrow has a
smooth bright reflector that provides a narrower 8ş symmetric beam angle. Optical
chambers are sealed to reduce dirt and insect contamination. Both fixtures use ED17
envelope lamps and are ideal for illuminating tall, narrow subjects such as flagpoles,
steeples, columns and signs. A metal halide version of the Axial Parabolic fixture is
also available with G12-base tubular lamp.
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
Axial Parabolic Medium
3
= 2" Adjustable Fitter
12" 150W PSMH MAM
*
615-M
4
= Yoke Mount
1 2" 50W MH MAM
*
405-D
6
= 1/2" Adjustable Fitter
1 2" 70W MH MAM
*
407-D
8
= Without Mounting (hardware)
1 2" 100W MH MAM
*
410-D (factory-drilled)
12" 175W MH MAM
*
417-M
12" 70W MH* MAM
*
707-D
12" 150W MH* MAM
*
715-M
12" 35W HPS MAM
*
503-I
12" 50 HPS MAM
*
505-D
12" 70 HPS MAM
*
507-M
12" 100 HPS MAM
*
510-M
12" 150 HPS MAM
*
515-M
Axial Parabolic Narrow
12" 150W PSMH MAN
*
615-M
12" 50W MH MAN
*
405-D
12" 70W MH MAN
*
407-D
12" 100W MH MAN
*
410-D
12" 175W MH MAN
*
417-M
12" 70W MH* MAN
*
707-D
12" 150W MH* MAN
*
715-M
12" 35W HPS MAN
*
503-1
12" 50W HPS MAN
*
505-D
12" 70W HPS MAN
*
507-M
12" 100W HPS MAN
*
510-M
12" 150W HPS MAN
*
515-M
*G12 Ceramic Metal Halide tubular lamp
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast (150W PSMH only)
27
120V Reactor ballast
( 50– 150W HP S 12" housi ng only )
1
480V ballast
( 175W M H & 70–15 0W H PS onl y )
5
Quad-volt ballast (50–100W MH only)
M
Tri-volt ballast (70–175W MH & 70–150W HPS only) T
(Canada only)
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Uplight Lens Frame
U
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter)
NOTE: n/a on 480V
27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 131) 5 P
For fixtures w/480V
Linear spread lens– horizontal
X
Linear spread lens– vertical
Y
Accessories: (Field-installed)
Catalog#
Deep Baffle
DB-12
Wire Guard
FWG-12
Glare Shield
GS-12
Polycarbonate Vandal Shield
LS-12
Internal Louver
DL-12A
Button Photocell
( Fi el d-i nst a ll ed in fi x tur e s w it h 2" Ad jus ta bl e Fit te r )
Catalog #
For fixtures w/120V
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
120
Mini Axial Parabolic Floodlight
Lamp
MAM/ MAN Series Order Information
Lamp
Included!
MAM Series
2" Adjustable Fitter
MAN Series
2" Adjustable Fitter
Candlepower trace through origin 150W
PSMH Mini Axial Parabolic Narrow.
Isofootcandle plot of 150W PSMH
Mini Axial Parabolic Narrow at 20'
(6.1 m) mounting height, 60° tilt above
horizontal.
0' 10'
1 0' 2 0'
20'
30 '
30 '
30'
20'
10'
0'
10'
20'
30'
40'
40'
9. 2
6. 1
3. 1
0 m
3. 1
6. 1
9. 2
12. 2
12. 2
40'
40 '
0 m 3.1
3. 1 6. 1
6.1
9. 2
9. 2
12. 2
12 .2
2 0
.5
2
2
1
5
1 0
8 0 0 00
7 2 0 00
6 4 0 00
5 6 0 00
4 8 0 00
4 0 0 00
3 2 0 00
2 4 0 00
1 6 0 00
80 0 0
0
4
8
12
1 6
4 8 12 1 6
A NG L E
(
IN D EG REES
)
- VE RT IC AL & H O RIZ O N TA L
0 ' 1 0'
10' 20'
2 0'
30'
30'
30 '
20 '
10 '
0 '
10 '
20 '
30 '
40 '
40 '
9 .2
6 .1
3 .1
0 m
3 .1
6 .1
9 .2
12 .2
12 .2
40 '
40'
0 m 3. 1
3. 1 6. 1
6. 1
9 .2
9 .2
12 .2
12. 2
2 0
.5
2
1
5
1 0
3 00 0 00
2 70 0 00
2 40 0 00
2 10 0 00
1 80 0 00
1 50 0 00
1 20 0 00
90 0 00
60 0 00
30 0 00
0
2
4
6
8
2468
A NG L E
(
IN D EG REE S
)
- V ERT IC AL & HO RI Z ON TA L
Candlepower trace through origin 150W
PSMH Mini Axial Parabolic Medium.
Isofootcandle plot of 150W PSMH
Mini Axial Parabolic Medium at 20'
(6.1 m) mounting height, 60° tilt above
horizontal.
www.ruudlighting.com
pg_0020
NPPG 121
NPPG 121
121
Sign Light (Uplight)
Lamp
Included!
W Series Order Information
Housing Wattage Catalog
Mounting Code
Size (sq.)Lamp Number
(Insert Code at
*
in Catalog #)
12" 150W PSMH MW
*
615-M
3
= 2" Adjustable Fitter
16" 320W PSMH W
*
632-M
4
= Yoke Mount
12" 50W MH MW
*
405-D
8
= Without Mounting (hardware)
12" 70W MH MW
*
407-D (factory-drilled)
12" 100W MH MW
*
410-D
12" 175W MH MW
*
417-M
16" 175W MH W
*
417-M
16" 250W MH W
*
425-M
16" 400W MH W
*
440-M
12" 35W HPS MW
*
503-1
12" 50W HPS MW
*
505-D
12" 70W HPS MW
*
507-M
12" 100W HPS MW
*
510-M
12" 150W HPS MW
*
515-M
16" 250W HPS W
*
525-M
16" 400W HPS W
*
540-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH.
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( PS MH only )
27
120V Reactor ballast
(50–150W HPS 12" housing only)
1
480V ballast
(32 0W P SM H , 175–4 00W M H & 70– 400W H P S only )
5
Quad-volt ballast (50–100W MH only)
M
Tri-volt ballast (320W PSMH,
T
70–400W MH & 70–400W HPS) (Canada only)
NOTE: In Canada, 50W fixtures are supplied with Dual-volt (120/277V) ballasts.
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
(delay-relay type) (includes 100W Q Lamp) (n/a 277V Reactor)
Q
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter)
(n/a on 480V) (277V Reactor, 120V, 277V, 208V, 240V or 347V)
27,1, 2, 3, 4 or 6 P
External Photocell (Factory-installed)(Page 131)
For fixtures w/480V
5 P
Accessories: (Field-installed)
Catalog #
Catalog #
Description
12" housing 16" housing
Wire Guard
FWG-12
FWG-16
Glare Shield
GS-12
GS-16
Button Photocell
(Field-installed in fixtures with 2" Adjustable Fitter)
Catalog #
For fixtures w/120V
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Housing
The seamless, die-cast aluminum
housing is standard with our exclusive
DeltaGuard
®
finish, featuring an E-coat
epoxy primer with bronze ultra-durable
powder topcoat. Consult factory for
availability of other finish colors.
Two sizes: 12" (305 mm) square x 5"
(127 mm) deep and 16" (406 mm)
square x 6.5" (165 mm) deep.
Optics
A precision specular reflector provides a
cutoff distribution to assure maximum
fixture spacings and optimum light
levels. The clear tempered-glass lens
is enclosed in a hinged lens frame. The
optical chamber is sealed to reduce dirt
and insect contamination.
Lens
A clear tempered-glass lens is held
securely in a die-cast doorframe. The
lens frame is supplied with mounting
holes for field-installed accessories,
such as the Wire Guard
or Glare Shield.
Ballast
All fixtures are standard with a high-
power-factor ballast. The 35-watt HPS
fixture is standard with a 120-volt
ballast. The 50-, 70- and 100-watt MH
and 50-watt HPS fixtures are standard
with a dual-volt (120/277V) ballast. In
the US, all other wattages
are standard with a quad-volt
(120/208/240/277V) ballast. In Canada,
150- and 320-watt PSMH, 70-to-400-
watt MH and 70-to-400-watt HPS
fixtures are supplied with a tri-volt
ballast (120/277/347V), 50-watt MH
and HPS fixtures are supplied with a
dual-volt ballast (120/277V). See order
information chart for additional ballast
options.
Lamps
The 12-inch sq. housing accommodates
150W PSMH, 50-175W MH and 35-
150W HPS medium-base lamps. The
16-inch sq. housing accommodates
320W PSMH, 175-400W MH and 250
or 400W HPS mogul-base lamps.
Gasketing
Complete silicone gasketing around
lens frame and at mounting provide a
watertight seal.
Labels
UL Listed in the US and Canada for wet
locations and enclosure classified IP65
per IEC 529 and IEC 598.
180
°
150
°
10000
120
°
20000
90
°
Candlepower Distribution Curve
400W MH Sign Light. For optimum use,
position fixtures 5' (1.5 m) away and 2'
(0.6 m) below the sign.
8 ' 1 2 ' 1 6 ' 2 0 ' 2 4 ' 2 8 ' 3 2 ' 3 6 ' 4 0 '
69 .5
91 .8
1 22
1 58
1 88 22 7
20 5
14 6
10 9
80 .3 7 8.2
9 8.8
13 0
16 6
19 6 1 37
1 18
10 7
97. 5
8 2. 3 84 .6
97 .5
95 .6
99 .9
93 .1 13 7
1 19
108
99 .2
83 .9 8 1.5
10 3
13 4
16 9
19 7 23 0
21 1
15 3
11 6
8 6.1 82. 0
1 03
1 34
1 69
1 97 1 37 93 .4
10 1
1 20
1 09 97 .2
1 00 99 .3
86 .3
84 .9
46 .8 51 .8 5 6.5 6 1. 9 63 .8 63 .2 59 .4 5 8.0 59. 9 64 .2 65 .3
1 38 17 0 14 0 7 0. 7 30 .6 70 .8 14 0 17 0 1 40 70 .9 30 .7
2 00
1 30
1 10
90
7 0
2 00
1 30
1 10
1 2 ' ( 3. 7 m ) Ty p ic a l S p a cin g
4 '
0 '
0 '
4 '
8 '
12 '
2 . 4 3 . 7 4 .9 6 . 1 7 .3 8 . 5 9 . 8 1 1 1 2 .2
1 .2
0 m
0 m
1 .2
2 .4
3 .7
2 ' (0 . 6 m )
Front view billboard, showing footcandle levels achieved with four 400W Super MH
Sign Lights at 12' (3.7 m) spacing. Fixtures are 2' (0.6 m) below and 5' (1.5 m) in front
of the sign.
W3 Series
2" Adjustable Fitter
NOTE: Consult factory if
using as a downlight
www.ruudlighting.com
pg_0021
NPPG 122
NPPG 122
122
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
12" 150W PSMH MAC
*
615-M
1
= 1-1/2" Close Pole Mount
16" 320W PSMH AC
*
632-M
2
= 6" Extended Pole Mount
22" 750W PSMH AC
*
675-M
3
= 2" Adjustable Fitter
12" 50W MH MAC
*
405-D
4
= Yoke Mount
12" 70W MH MAC
*
407-D
6
= 1/2" Adjustable Fitter
12" 100W MH MAC
*
410-D
(12" housing only)
12" 175W MH MAC
*
417-M
K
= Round Tube Off-Center
16" 175W MH AC
*
417-M
Tenon Mount (16" housing only)
16" 250W MH AC
*
425-M
(For 2-3/8" or 3" O.D.)
16" 400W MH AC
*
440-M
M
= Round Tube Off-Center
22" 1000W MH AC
*
499-M
Direct Mount (16" housing only)
12" 35W HPS MAC
*
503-1
(Direct Fitter for 4" sq. pole)
12" 50W HPS MAC
*
505-D
W
= Wall Mount
12" 70W HPS MAC
*
507-M
(Backlight Shield is standard)
12" 100W HPS MAC
*
510-M
8
= Without Mounting (hardware)
12" 150W HPS MAC
*
515-M
16" 250W HPS AC
*
525-M
16" 400W HPS AC
*
540-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320W PSMH and 400W MH; BT37 for 1000W MH.
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( PS M H onl y)
27
120V Reactor ballast (50–150W HPS 12" housing only) 1
480V ballast
( 320W PSM H , 175– 1000W M H & 70–400W H PS onl y)
5
Quad-volt ballast (50–100W MH only)
M
Tri-volt ballast (320W PSMH,
T
70–1000W MH & 70–400W HPS only) (Canada only)
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
(delay-relay type) (includes 100W Q lamp) (n/a 277V Reactor)
Q
Button Photocell (Factory-installed with all mountings other than 2" Adjustable Fitter)
NOTE: n/a on 1000W w/120V; all 480V 27, 1, 2, 3, 4 or 6 P
External Photocell (Factory-installed) (Page 131)
For fixtures w/1000W, 120V
1 P
For fixtures w/480V
5 P
Accessories: (Field-installed)
12" housing 16" housing 22" housing
Wire Guard FWG-12
FWG-16
FWG-22
Backlight Shield SBL-12
SBL-16
SBL-22
(standard on AC Series Wall Mount)
Button Photocell
( Fie ld- ins ta l le d i n f ix t ur es wi th 2" Adj ust a ble Fi tt e r)
Catalog #
For fixtures w/120V (n/a on 1000W)
PC-1
For fixtures w/208, 240 or 277V
PC-2
For fixtures w/347V
PC*6
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
This compact forward-throw reflector has a main beam of 60°+ from vertical (30° from
horizontal), providing wide lateral distribution and excellent uniformities. A Backlight
Shield accessory (standard on Wall Mount) permits precise cutoff adjustability.
Three Sizes:
12" square x 5" deep (305 x 127 mm)
16" square x 6.5" deep (406 x 165 mm)
22" square x 9.25" deep (559 x 235 mm)
Area Cutoff Light
Lamp
Included!
AC Series Order Information
AC Series
6" Extended Pole Mount
180
°
150
°
120
°
90
°
60
°
10000
30
°
20000
Candlepower distribution curve of 400W
MH 16" Area Cutoff Floodlight.
40'
20'
0'
20'
40'
60'
80'
100'
120'
140'
160'
40 '
60'
80'
100' 20' 0' 2 0' 40' 60 ' 80' 10 0'
5
3
1
. 0 5
.5
. 1
12 .2
6. 1
0 m
6. 1
12 .2
18 .3
24 .4
30 .5
36 .6
42 .7
48 .8
1 2 .2
1 8 .3
2 4. 4
3 0 .5 6 .1 0 m 6 .1 1 2 .2 1 8 .3 2 4 .4 3 0 .5
8 0 '
6 0 '
4 0 '
2 0 '
0 '
2 0 '
4 0 '
6 0 '
8 0 '
2 4 . 4
1 8 . 3
1 2 . 2
6 . 1
0 m
6 . 1
1 2 . 2
1 8 . 3
2 4 . 4
0 ' 2 0 ' 4 0 ' 6 0 ' 8 0 '
2 0 '
4 0'
6 0 '
8 0 '
0 m 6 .1 12 .2 18 .3 24 .4
6. 1
1 2.2
1 8. 3
24. 4
.
1
1
3
5
.
3
.
5
Isofootcandle plot of 175W MH
Area Cutoff Floodlight at 15' (4.6 m)
mounting height, 0° tilt above
horizontal, with backlight shield
located for backlight cutoff.
4 0 '
2 0 '
0 '
2 0 '
4 0 '
6 0 '
8 0 '
1 0 0 '
1 2 0 '
1 4 0 '
1 8 0 '
4 0 '
6 0'
8 0 '
1 00 ' 2 0 ' 0 ' 2 0' 40 ' 6 0 ' 8 0 ' 1 0 0 '
1 0
5
3
1
. 5
2 0
.1
1 2 .2
6 0 '
1 8 .3
6 .1
0 m
6 .1
1 2 .2
1 8 .3
2 4 .4
3 0 .5
3 6 .6
4 2 .7
4 8 .8
1 6 0 '
5 4 .9
12 .2
1 8.3
2 4.4
30 .5
1 2 0'
36 .6 6.1 0 m 6 .1 12 .2 18 .3 24 .4 3 0.5
1 2 0'
36 .6
Isofootcandle plot of 400W MH
Area Cutoff Floodlight at 25' (7.6 m)
mounting height, 0° tilt above horizontal,
with backlight shield removed.
Isofootcandle plot of 1000W MH
Area Cutoff Floodlight at 30' (9.1 m)
mounting height, 0° tilt above horizontal,
with backlight shield removed.
NOTE: When using multiple 22" sq.
housings at 90° configuration, a special 12"
arm is required; see page 148.
www.ruudlighting.com
pg_0022
NPPG 123
NPPG 123
The VFT Series fixture features a 70° main beam. Inside the housing, the lamp is
tilted 20° from vertical toward the house-side of the fixture. The Vertical Forward
Throw is ideal for use in wide roadway areas and large parking areas. It provides low
nadir candlepower and great forward and lateral distribution.
One Size:
22" square x 9.25" deep (559 x 235 mm)
123
Vertical Forward Throw Light
Lamp
Included!
VFT Series Order Information
Housing Wattage/ Catalog
Mounting Code
Size (sq.) Lamp Number
(Insert Code at
*
in Catalog #)
22" 250W PSMH VFT
*
6925-M
1
= 1-1/2" Close Pole Mount
22" 320W PSMH VFT
*
6932-M
2
= 6" Extended Pole Mount
22" 400W PSMH VFT
*
6940-M
W
= Wall Mount
22" 750W PSMH VFT
*
675-M
8
= Without Mounting (hardware)
22" 1000W PSMH VFT
*
699-M (factory-drilled)
22" 250W MH VFT
*
492-M
22" 400W MH VFT
*
494-M
22" 1000W MH VFT
*
499-M
22" 250W HPS VFT
*
592-M
22" 400W HPS VFT*594-M
Other lamp wattages available– consult factory
Reduced envelope lamp. ED28 for 320 & 400W PSMH and 400W MH; BT37 for 1000W PSMH & MH.
Options: (Factory-installed)
Change Add After
Description
Suffix To Suffix
277V Reactor Ballast
( P SM H o nly )
27
480V ballast
5
Tri-volt ballast (Canada only)
T
Single Fuse (277V Reactor, 120V, 277V or 347V) 27, 1, 2 or 6 F
Dual Fuse (208V, 240V or 480V)
3, 4 or 5 F
Quartz Standby
(delay-relay type) (includes 100W Q lamp) (n/a 277V Reactor)
Q
Button Photocell
27, 1, 2, 3, 4 or 6 P
NOTE: n/a on 1000W w/120V; all 480V
External Photocell (Factory-installed) (Page 131)
For fixtures w/1000W, 120V
1 P
For fixtures w/480V
5 P
2- Level available – consult factory
Accessory (Field-installed)
Catalog Number
Backlight Shield
SBL-22
Mountings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 114
Catalog Number Logic/Voltage Suffix Key . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 113
Optical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 103–105
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 131
Mounting Alternatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 148–149
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 150–151
Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 152–155
VFT Series
6" Extended Pole Mount
10000
15000
0
°
60
°
30
°
5000
90
°
1 4 0 '
1 2 0 '
1 0 0 '
8 0 '
6 0 '
4 0 '
2 0 '
0 '
2 0 '
4 0 '
6 0 '
8 0 '
1 0 0 '
1 2 0 '1 0 0 ' 8 0 ' 6 0 ' 4 0 ' 2 0 ' 0 ' 2 0 ' 4 0 ' 6 0 ' 8 0 ' 1 0 0 ' 1 2 0 '
.0 5
5
3
1
.5
.1
4 2 .7
3 6 . 6
3 0 . 5
2 4 . 4
1 8 . 3
1 2 . 2
6 . 1
0 m
6 . 1
1 2 . 2
1 8 . 3
2 4 . 4
3 0 . 5
3 6.6 3 0. 5 2 4.4 1 8.3 1 2.2 6. 1 0 m 6 .1 1 2. 2 1 8 .3 2 4.4 3 0.5 3 6. 6
14 0 '
16 0 '
12 0 '
10 0 '
8 0 '
6 0 '
4 0 '
2 0 '
0 '
2 0 '
4 0 '
6 0 '
8 0 '
10 0 '
12 0 '
4 2. 7
4 8. 8
3 6. 6
3 0. 5
2 4. 4
1 8. 3
1 2. 2
6. 1
0m
6. 1
1 2. 2
1 8. 3
2 4. 4
3 0. 5
3 6. 6
12 0 '
14 0 ' 1 00 ' 8 0 ' 6 0 ' 4 0' 2 0' 0 ' 2 0 ' 4 0' 6 0 ' 8 0' 1 00 ' 12 0 ' 1 40 '
36. 6
42. 7 30 . 5 24 . 4 18 . 3 12 . 2 6. 1 0 m 6 . 1 12. 2 18 . 3 24. 4 3 0. 5 36 . 6 42 . 7
5
. 5
. 1
3
1
1 4 0 '
1 2 0 '
1 0 0 '
8 0 '
6 0 '
4 0 '
2 0 '
0 '
2 0 '
4 0 '
6 0 '
8 0 '
1 0 0 '
1 2 0 '
1 4 0 '
1 2 0 '1 0 0 ' 8 0 ' 6 0 ' 4 0 ' 2 0 ' 0 ' 2 0 ' 4 0 ' 6 0 ' 8 0 ' 1 0 0 ' 1 2 0 '
. 05
.1
.5
1
3
5
4 2 . 7
3 6 . 6
3 0 . 5
2 4 . 4
1 8 . 3
1 2 . 2
6 . 1
0 m
6 . 1
1 2 . 2
1 8 . 3
2 4 . 4
3 0 . 5
3 6 . 6
4 2 . 7
3 6 .6 3 0.5 2 4.4 1 8.3 1 2.2 6.1 0 m 6.1 1 2. 2 18 .3 2 4 .4 30 .5 3 6 .6
Isofootcandle plot of one 1000W MH
Vertical Forward Throw Light at 30'
(9.1 m) mounting height, 0° tilt above
horizontal.
Candlepower Distribution Curve of
400W MH Vertical Forward Throw light.
Isofootcandle plot of two 400W MH
Vertical Forward Throw Lights at 25'
(7.6 m) mounting height, 0° tilt above
horizontal.
Isofootcandle plot of one 400W MH
Vertical Forward Throw Light at 25' (7.6 m)
mounting height, 0° tilt above horizontal.
4"
(102 mm)
2.5" (64 mm)
70°
Cutaway view of a 1000W MH Vertical Forward Throw light, showing the lamp
positioned 20° from vertical and the main beam directed 70° from nadir. 4" sq. x 2.5" H
(102 mm x 64 mm) cast aluminum, gasketed box supplied on 750 and 1000W PSMH,
1000W MH and 250–400W HPS fixtures.
NOTE: When using multiple 22" sq. housings
at 90° configuration, a special 12" arm is
required; see page 148.
www.ruudlighting.com