NPPG 183
183
Luma Low-Voltage (12V)
Landscape Lighting System
The same great quality,
performance and ease of
installation you have come to
know from Ruud
®
is
available in our Luma After-
Sunset Low-Voltage (12V)
Landscape Lighting System.
Whether your customer’s
desire is to provide
decorative accent lighting or
to increase security, the
Luma line will help you
design a system to meet their
needs.
Path Lights
Perfect for walkways,
borders, steps, driveways,
flowerbeds and entrances,
Luma path lights look
graceful by day, warm and
inviting by night.
Directional Lights
For a dramatic look, Luma
directional lights can create
shadow effects, uplight
through branches, spotlight a
tree or flowering shrub,
highlight a piece of sculpture
or accent the architectural
details of a building.
Step Lights
Embedded fixtures for stair
lighting will complement
brick, stone or wood
stairwells as well as provide
added safety.
Outdoor 12-Volt Track
Patios open up with the
addition of Luma 12-volt
track lighting. In fact, our
track is so versatile it can be
mounted in trees, snaked up
a trellis or installed around a
pool deck.
Lum
a A
fter-Sunset
®
GL41 Path Light
Page 190
DF Series (Directional Flood), Page 208
DU Series (Sealed Well Light), Page 210
DRC Series Fixtures (Retractable Bollard)
Page 189
www.ruudlighting.com
pg_0002
NPPG 184
184
Sturdy Construction
Luma After-Sunset
®
is a low-
voltage (12V) system that
includes high-quality, die-
cast aluminum or solid-brass
fixtures; substantial weather-
resistant, self-sealing, 10-
gauge, 3-wire cable; 300-
watt or 600-watt dual circuit
transformers that pack more
power than “off-the-shelf"
products. The Luma system
combines the best power-
handling capability with ease
of installation and operation.
Superior Performance
With the Luma dual-circuit
12-volt system using 10/3
cable, voltage drop is
reduced by as much as 75
percent over traditional 12-
volt systems using 12-gauge
wire. Luma cable is never
spliced, and the dual-circuit
design balances the total
wattage load.
Superior Finish
Luma ensures that the,
daytime appearance of your
landscape lighting will
remain as perfect as the
nighttime performance
because fixtures are
protected by the
exclusive
DeltaGuard
®
finish. This
E-coating and
ultra-durable topcoat
finishing process defeats
whatever nature throws at it,
and it’s guaranteed for seven
years.
Compact Fixtures
Because of the remote
transformer, individual Luma
fixtures are scaled correctly
for use around residences,
office entrances or atriums.
Whether a path or directional
light, Luma products nestle
into the landscape, so they
are discreet by day, dynamite
at night.
Complete Safety
UL Listed in the US, Luma
10/3 cable is UV-stabilized
and flame retardant. It can be
used above or below ground.
The specially formulated
insulation is self-sealing,
enabling connectors to be
removed and reinstalled
anywhere along the cable.
And there is no safety
concern, even if the cable is
inadvertently nicked by
garden tools.
Patented Connector
System
The design simplicity of the
Luma fixture pigtail
connector reduces time and
cost of installation by as
much as 90 percent over
competitive systems. The
nickel-plated beryllium
copper connector pins pierce
the insulation and make
contact with the wires deep
within the cable. This keeps
moisture from getting into
the contact area.
Energy Savings
The precise beam patterns of
low-voltage light sources
eliminate wasted spill light
and glare while saving
energy. For example, a 75-
watt narrow spot produces
the same center beam
candlepower as a standard
150-watt PAR38 spot
incandescent with less total
lumens and 50 percent less
energy. And our exclusive
12-volt compact fluorescent
fixtures provide excellent
energy savings for general
lighting needs.
Note: All Luma
®
low voltage
landscape fixtures are
designed for use with only
Luma transformers and
Luma cable. Installation of
Luma fixtures with non Luma
components, or any physical
modification of Luma
products, may lead to fixture
malfunction or failure and
will void all warranty or
obligation from Ruud
Lighting, Inc.
Connector
Connector Cover
Pigtail
Wires
3-Wire Main Cable
Connector Spine
or Track
Alternate direction
of connector for
2nd circuit
Y
Relative Height Comparison
24"
(610 mm)
12"
(305 mm)
24"
(610 mm)
12"
(305 mm)
GL20
PATH LIGHTS
DIRECTIONAL LIGHTS
GL 23
WE L L
L I G HT
GL2 3S
W EL L
L I G H T
GL4 9
GL 09
GL1 9
GL4 4
GL4 5
GL 48
GL 47
GL 41
GL60
DR S e rie s
GL 80
GL8 1
GL7 0
SE AL E D
WE LL
L I G HT
GL 71
S EA L ED
W EL L
L IG H T
NS 621 3
NPPG 184
www.ruudlighting.com
pg_0003
NPPG 185
185
Luma After-Sunset
®
Planning
In commercial applications, the Luma low voltage (12V) landscape lighting system is
perfect for creating visual impact in a subtle yet effective way. Luma low voltage track
lights illuminate the corporate logo behind the reception desk. An atrium comes to life
when directional fixtures uplight trees. And outside when the sun sets, micro floods
provide effective sign lighting; bollards illuminate the entryway and the building’s
texture is emphasized by the grazing light of directional fixtures.
By daylight or moonlight, Luma After-Sunset landscape lighting is a beautiful addition
to any residence. Pathlight fixtures with graceful daytime appearance line the entryway
and assure safer passage by night. Directional fixtures provide dramatic shadow
lighting in front and backyards. And the safety of Luma low voltage track lighting
is ideal around swimming pools or spas.
Planning for the
Luma Low-Voltage (12V)
Landscape Lighting System
The paradox of landscape lighting is
that “less is more." By strategically
locating fixtures around a structure,
pools of light contrast with dark areas.
It is this interplay of light and shadow
that creates stunning visual impact.
Unlike 120-volt systems that require
buried cable, low-voltage lighting is
easily installed, making it ideal for
enhancing existing properties. The
design of each installation is tailored to
the unique characteristics
of the property’s foliage, structures and
human activities. With an understanding
of the variety of lighting effects in mind,
these questions come into play:
1. What sections and/or objects are to
be illuminated.
2. What combination of lamps and
fixtures will produce the desired
effect.
3. How much transformer power does
this lighting equipment require.
Sketch the Property
Begin by walking the property with an
objective eye. The front sidewalk or
driveway is a natural starting point.
Sketch the structure (house or office
building) in context on the lot, and make
note of trees for uplighting, interesting
textures, signs or address markers, and
colorful flowerbeds and shrubbery.
Lighting invites people into a space by
making it reassuring and enticing. Both
interior and exterior spaces benefit from
the sparkle of low-voltage lighting with
its superior color-rendering capabilities.
Rank Lighting Possibilities
Make a list of all the areas and items
that are candidates for lighting, then
rank them in order of importance. Again,
remember to plan conservatively. Low-
voltage lamps are on average three
times brighter per watt than line-voltage
lamps. Try to visualize driving up to the
house or business first from one
direction, then from the other. It is
usually more attractive when the lighting
effects are spread throughout the setting
rather than merely aimed for
symmetrical distribution.
Create a Plan
Drawing up a plan is critical, as it will
be referred to many times. Important
points to include in the layout: house
outline, walks, patios, decks and pools
or other water features. Mark in all the
areas previously identified for lighting.
It is imperative to show the number and
accessibility of GFI outlets.
Indicate Fixture Locations
Once the plan is complete, pencil in the
placement of path and directional
fixtures. Path lights are used for
walkways, flowerbeds and ground-cover
areas, with spacing of 6 to 10 feet
(1.8–3.0 m). With a narrow sidewalk,
stagger the lighting from one side to the
other; however, a uniform row of fixtures
works very well for a wide walkway or
driveway.
Well lights are extremely effective for
aiming light up a tree or column;
they should be located 2 to 4 feet
(0.6–1.2 m) out from the trunk. As the
name implies, directional lights aim a
beam directly at an object or surface.
These fixtures can be hidden under
shrubs or in other unobtrusive ways.
While path lights are supplied with an
18-watt lamp, directional fixtures offer a
range of lamp choices and beam
spreads.
Refer to the lamps on page 287 to aid
with your decision-making. When the
lamp wattage is known, the transformer
calculation is easy (see page 186). Just
add up the total wattage of lamps you
are using and make sure it is less than
or equal to the transformer. If it exceeds
the amount, more than one transformer
may be needed. Try to leave extra space
on the transformer for future expansion.
Commercial Installation
Considerations
Commercial installations require more
concentrated lighting layouts. There
may be competition from ambient light
in a shopping district or strip center; the
HID lights in the parking lot may wash
out lower wattage effects. Luma is the
right choice because of the long-term
durability of metal components, the
12-volt safety factor, and the no-splice
connector design that minimizes
voltage drop.
Luma Track delivers the powerful punch
of MR16 and MR11 in petite fixtures
with some that are UL Listed for wet
locations. Both retail and restaurant
owners will find this track system
extremely flexible.
K ey
Mi cro F loo d
Track Fi xt ures
Di rect i on al Fixt u res
K ey
P at h Li gh t s
Track Fi xt ures
Di rect i onal Fixt u res
Tran sf orm er
www.ruudlighting.com
pg_0004
NPPG 186
186
Photocell/Time Clock (-4)
(shown with cover removed)
The Photocell-ON/Time Clock-OFF
option means no daily manual control
is necessary. Because it is controlled by
a photocell, the lighting will click on
at dusk regardless of the season. The
fixtures operate during a period of time
the owner determines, then the time
clock automatically turns off the system.
Photocell/Time Clock & Rotary
Dimmer (-7)
(shown with cover removed)
The Photocell-ON/Time Clock-OFF
option means no daily manual control
is necessary. Because it is controlled by
a photocell, the lighting will click on at
dusk regardless of the season. The
fixtures operate during a period of time
the owner determines, then the time
clock automatically turns off the system.
Integral dimmer provides continuous
dimming for incandescent and quartz
fixtures only.
NOTE: Dimmer does not work with
fluorescent fixtures.
Electrical
Standard Transformers
Magnetic transformer is available in 300
and 600 watts, with 12/24-volt dual
circuit. Amps: 2.5 for the 300 watt, 5.0
for the 600 watt. Rocker-type ON/OFF
switches, with built-in circuit breakers
provided for each 12-volt circuit.
Breaker switches are thermally
insensitive and allow each circuit to be
switched independently.
Heavy-duty terminal lugs are provided
for the 12-volt cable connectors.
Terminals are provided for each circuit,
which makes it easy to split branch
circuits and loop systems. The 6-foot
(1.8 m) power cord plugs into a 120-
volt GFI receptacle; unit may be
permanently wired.
Electrical
Direct Burial Transformers
Direct burial magnetic transformer is
available in 300 watts with 12/24-volt
dual circuit, 2.5 amps. Internal, rocker-
type ON/OFF switches, with built-in
circuit breakers provided for each 12-
volt circuit. Breaker switches are
thermally insensitive and allow each
circuit to be switched independently.
Transformer includes wiring
compartment with two -inch entry points
and one watertight entry for Luma low-
voltage cable. Silicone potting
compound is used to prevent siphoning
of moisture through conduit during cool
down. Also available with optional
internal timer.
NOTE: Pea gravel required (not
supplied) as backfill around transformer
for proper drainage.
Construction
Constructed of heavy-duty aluminum
with slide lock door. Exclusive
DeltaGuard
®
black finish. Isolation-type
vacuum impregnated transformer for
safety and quiet operation. Key-hole
mounting for ease of installation.
Labels
UL Listed for wet locations.
Luma After-Sunset
®
Transformers
Transformer Order Information
Direct Burial Transformer
Available in 300W
Standard Transformer
Available in
300W and 600W
Catalog
Description
Wattage Number
Standard Transformer (manual control)
300W TO24300
8.2"L x 4.5"W x 4.8"D (208 x 114 x 122 mm)
Transformer with Photocell/Time Clock
300W TO24300-4
12.6"L x 4.5"W x 4.8"D (319 x 114 x 122 mm)
Transformer with Photocell/Time Clock & Rotary Dimmer 300W TO24300-7
20.3"L x 4.5"W x 4.8"D (514 x 114 x 122 mm)
Standard Transformer (manual control)
600W TO24600
15.6"L x 4.5"W x 4.8"D (395 x 114 x 122 mm)
Transformer with Photocell/Time Clock
600W TO24600-4
20.3"L x 4.5"W x 4.8"D (514 x 114 x 122 mm)
Transformer with Photocell/Time Clock & Rotary Dimmer 600W TO24600-7
25.3"L x 4.5"W x 4.8"D (641 x 114 x 122 mm)
Direct Burial Transformer
300W TB24300
(Use with any low voltage fixture)
8"H x 6.3" sq. (203 x 160 mm)
Direct Burial Transformer with Internal Timer
300W TB24300-1
(Use with any low voltage fixture)
8"H x 6.3" sq. (203 x 160 mm)
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
L
W
D
0.4"
(10 mm)
0.4"
(10 mm)
8.0"
(203 mm)
7.6"
(193 mm)
0.4"
(10 mm)
2.4"
(61 mm)
9.7"
(245 mm)
6.3" sq.
(160 mm)
0.4" (10 mm)
Direct Burial Transformer
NPPG 186
www.ruudlighting.com
pg_0005
NPPG 187
187
Determining Cable Length for Ordering
1. Figure the total wattage (both circuits combined) of the fixtures to be used on the
system.
2. Locate this number along the “Wattage Total" at the bottom of the Recommended
Cable Length chart.
3. Follow the line up until you reach the RED “10/3 Luma Cable" line.
4. Read across the chart to “Distance in Feet." This is the maximum recommended
length of cable for your system.
Example A-Single Feed: One cable exiting transformer. One 300-watt transformer with
a 220-watt total load (110W per circuit). Recommended maximum cable length is 215
feet (66 m).
Example B-Dual Feed: Two separate cables exiting the transformer (possibly one to the
front yard, one to the back yard). Cables may be of unequal length. One 600-watt
transformer with Cable B1 maintaining a 30-watt total load (150 watts per circuit), and
Cable B2 maintaining a 200-watt total load (100 watts per circuit). Recommended
maximum B1 Cable length is 150 feet (45.8 m). Recommended maximum B2 Cable
length is 225 feet (69 m).
Example C-Loop Feed: One continuous cable coming back around to the transformer.
One 300-watt transformer with 150-watt total load (75 watts per circuit).
Recommended maximum cable length is 650 feet (198 m).
Cable Construction
Luma heavy-duty #10 gauge
3-wire cable allows longer runs and
greatly reduces voltage-drop problems
found in typical #16 to #12 gauge
2-wire systems. Luma 10/3 cable, UV-
stabilized and flame retardant, can be
installed above ground or buried. The
specially formulated insulation in Luma
cable is self-sealing, which enables
connectors to be removed and
reinstalled anywhere along the cable.
Benefits of Luma Cable
Getting rid of voltage drop means you
can use more lamps and go for longer
distance runs —getting the light to
where it’s needed. The voltage chart
demonstrates the dramatic advantage of
10/3 using Luma Cable over 12/2
systems. Solving the voltage-drop
problem offers you a lot more flexibility
in laying out a system while reducing
the number of transformers needed.
Luma cable’s self-sealing design offers
reliable connection and relocation of
fixtures over the life of the installation.
Patented Pigtail Connector
All Luma fixtures (except track fixtures)
have a patented 5-foot (1.5 m) pigtail
connector that allows for quick and easy
connection to the cable. This unique
design allows the nickel-plated
beryllium copper connector pins to
pierce the cable and make electrical
contact inside the insulation. No
moisture ever intrudes into the contact
area. One of the main advantages of the
Luma low-voltage (12V) system is that
you don’t cut and splice the main cable,
eliminating voltage drop and conductor
corrosion.
Labels
UL Listed in the US for wet locations.
Luma After-Sunset
®
Cable
Cable Order Information
Easy to
Connect!
Self-
Sealing!
Easy
to Move!
Catalog
Number Description
PC103C-BK Black 10/3 Luma Cable Order in 10' increments
PC103C-WH White 10/3 Luma Cable Order in 10' increments
Cut Charge for Lengths Under 100'
PC122C-BK Black 12/2 Cable (250') (supplied with TR1-12BK(20)
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
0
50
100
150
200
250
300
350
400
450
500
550
600
650
100 200 300 400 500 600
Wattage Total (on transformer)
0
15
31
46
61
76
92
107
122
137
153
168
183
198
10/ 3
Lu ma C ab l e
C
B1
B2
A
1 0/ 2
C ab l e
12/ 2
C abl e
Voltage Drop problems are solved with our premium 10/3 Luma Cable. Use this chart
to compare 10/3 cable to the typical 12/2 cable and see the dramatic Luma advantage
in distance and total wattage load.
Recommended Cable Length
www.ruudlighting.com
pg_0006
NPPG 188
R
etractable B
ollard
Ruud Lighting’s Retractable
Bollard (DR Series) brings
nighttime landscapes alive
without taking away their
daytime beauty. The fixture
vanishes into the ground when
not in use and reappears only
when needed.
The Retractable Bollard rises
13.1 inches (333 mm) above
grade when in use and has only
a 5-inch (127 mm) diameter at
grade level. A rigid PVC shell
firmly supports the fixture and
the operating components
below grade. All luminaires
take advantage of low-voltage
lamp sources to provide safe,
energy-efficient lighting with
brilliant accent or directional
illumination.
Low and Line Voltage
All low-voltage units have a
patented pigtail connector,
which quickly attaches to our
Luma (10/3) cable and our
Luma remote transformer
(available in 300-watt and
600-watt models).
An external wiring compartment
is included on line-voltage
models and is suitable for #10
feed-through wiring and
contains an energy-efficient,
electronic 12-volt step-down
transformer.
The Up/Down Movement
A unique rack-gear system
extends and retracts the
bollard. Applying power
energizes the system. First, the
inner fixture rises from its shell
within 15 seconds or less. Then
the lamp lights up, providing
188
brilliant illumination. Turning
the system off retracts the
fixture with power provided
from an internal long-life,
nickel metal hydride battery
(recharges when on). The
motor used to extend the inner
fixture does not add to total
system wattage (motor and
lamp never operate
simultaneously).
Borosilicate Glass Lens
Backlight Shroud
Adjustable Lamp Holder
Lamp Holder Support Bracket
Grade Level
Printed Circuit Board
Motor, Reduction Gears,
and Clutch Assembly
Drive Pinion
Rack Gear
DRD Series (MR16)
Typical Cutaway
Nickel Metal
Hydride Battery
www.ruudlighting.com
pg_0007
NPPG 189
Retractable Bollard
Fluorescent & T-5
Lamp Included!
DR Series Order Information
189
Catalog
Wattage/
Number Description Volts Lamp Type
Low-Voltage (12 Volt)
DRC105-L Clear Path 12 20–50W MR-16 bi-pin base †
DRD105-L Directional 12 20–50W MR-16 bi-pin base †
DRL118-L Louvered (Clear) 12 18W T-5 wedge base *
DRD213-L Directional 12 13W Fluorescent *
DRL213-L Louvered (Black) 12 13W Fluorescent *
Line-Voltage (120 Volt)
DRC105-1 Clear Path 120 20–50W MR-16 bi-pin base †
DRD105-1 Directional 120 20–50W MR-16 bi-pin base †
DRL118-1 Louvered (Clear) 120 18W T-5 wedge base *
†Order lamp separately.
*Lamp included.
Note: Pea gravel required (not supplied) as back fill around fixture for proper drainage.
UL Listed for wet locations
Options: (Factory-installed)
Add After
Description
Suffix
Black Louver (for 18W T-5 Incandescent only)
BK
Clear Louver (for 13W Fluorescent only)
CL
Accessories: (Field-installed)
Catalog
Description
Lampholder Number
Color Filters (for DRC or DRD only) 2" dia. (50 mm) MR16 TAF1*
*Specify color: A=Amber, B=Blue, G=Green or R=Red
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
DRC Series
DRD Series (MR16)
DRD Series (13W Fluorescent)
DRL Series
5.1"
(130 mm)
6.3"
(159 mm)
0.25"
(6 mm)
35.3"
(897 mm)
22.2"
(564 mm)
13.1"
(333 mm)
0.25"
(6 mm)
Grade
Level
DRC Series typical spacing 10'–20 (3–6 mm) '. Usage will var y by application.
Color Filters
TAF1*
www.ruudlighting.com
pg_0008
NPPG 190
190
Path Lighting
Concentric circles of light ripple out
from the fixture. Perfect for walkways,
borders, steps, driveways and entrances.
Typical spacing 8'–12' (2.4–3.7 m).
GL09
12V
Available in black or verde finish. GA05
stake, patented pigtail connector &
18W #1141 lamp included.
GL44
12V
Available in black or verde finish. GA05
stake, patented pigtail connector & 18W
#1141 lamp included.
Luma After-Sunset
®
Path Lighting
Path Lighting Order Information
GL19
12V
Available in black or verde finish. GA19
friction-fit stake, patented pigtail
connector & 18W #1141 lamp included.
GL45
12V
Available in black or verde finish. GA05
stake, patented pigtail connector & 18W
#1141 lamp included.
GL41
12V
Available in black or verde finish. GA07
friction-fit stake, patented pigtail
connector & 18W #1141 lamp included.
Catalog
Wattage/ Stake
Number Finish Volts Lamp Type Included
GL09-BK Black 12 18W #1141* GA05
GL09-VE Verde 12 18W #1141* GA05
GL19-BK Black 12 18W #1141* GA19
GL19-VE Verde 12 18W #1141* GA19
GL41-BK Black 12 18W #1141* GA07
GL41-VE Verde 12 18W #1141* GA07
GL44-BK Black 12 18W #1141* GA05
GL44-VE Verde 12 18W #1141* GA05
GL45-BK Black 12 18W #1141* GA05
GL45-VE Verde 12 18W #1141* GA05
*Lamp included. Maximum wattage–26W #1156 (order separately).
UL Listed for wet locations.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
Lamp
Included!
4. 8 "
(1 2 1 m m )
1 8 . 3 "
(4 63 m m)
1. 6 "
(4 1 mm )
Ø 0. 75 "
(1 9 m m )
17 . 5"
(4 4 5 m m)
8"
(2 03 mm )
Ø 1 "
( 25 mm )
3. 9 "
(1 00 m m)
7 . 3"
( 10 8 m m )
2 2. 3"
(5 65 m m )
ø 0. 39 7"
(1 0 m m )
6 "
( 15 2 mm)
5"
( 1 27 m m)
ø 0. 5 "
(1 3 mm)
1 7 "
(4 3 2 mm)
S t a ke
4 .5 "
( 1 1 4 m m )
1 2 .3 "
(3 1 1 m m )
Ø 1 "
( 2 5 mm )
3 .4 "
(8 6 mm )
GL09
GL44
GL19
GL45
GL41
NPPG 190
www.ruudlighting.com
pg_0009
NPPG 191
ø 2.5"
(64 mm)
14"
(356 mm)
191
Step Lighting—External
Placed next to deck or patio stairs,
a path light illuminates the risers
beautifully so people can move
about in confidence.
GL47
12V
Available in black or verde finish. GA05
stake, patented pigtail connector & 18W
#1141 lamp included.
GL60–14" H (1 lamp) 12V
Single directional bollard. Available in
black finish. GA19 friction-fit stake,
patented pigtail connector & 18W
#1141 lamp included.
Luma After-Sunset
®
Path Lighting
Path Lighting Order Information
GL48
12V
Available in black or verde finish. GA05
stake, patented pigtail connector & 18W
#1141 lamp included.
GL62–14" H (1 lamp) 12V
Dual directional bollard. Available in
black finish. GA19 friction-fit stake,
patented pigtail connector & 18W
#1141 lamp included.
GL49
12V
Available in black or verde finish. GA05
stake, patented pigtail connector & 18W
#1141 lamp included.
Catalog
Wattage/ Stake
Number Finish Volts Lamp Type Included
GL47-BK Black 12 18W #1141* GA05
GL47-VE Verde 12 18W #1141* GA05
GL48-BK Black 12 18W #1141* GA05
GL48-VE Verde 12 18W #1141* GA05
GL49-BK Black 12 18W #1141* GA05
GL49-VE Verde 12 18W #1141* GA05
Single Directional
GL60-BK Black 12 18W #1141* GA19
Dual Directional
GL62-BK Black 12 18W #1141* GA19
*Lamp included. Maximum wattage–26W #1156 (order separately).
UL Listed for wet locations.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
8 "
(2 0 3 m m )
2. 6 "
(6 6 mm )
21 . 5 "
(5 4 6 m m )
Ø 1 "
(2 5 m m)
20"
( 5 0 8 mm )
ø 0.75"
(1 9 mm)
5.4"
( 1 37 mm)
3.6"
(9 2 mm)
ø 2.5"
(64 mm)
14"
(356 mm)
GL60
GL48
GL62
GL49
4.5"
( 114 mm )
1.4"
( 36 mm )
20"
(50 8 m m)
ø 1"
( 24 m m )
GL47
Lamp
Included!
www.ruudlighting.com
pg_0010
NPPG 192
192
Directional Lighting
One or more ground-mounted fixtures
aimed straight-on at a specimen tree,
flowering bush or entranceway. Flood
or wide flood lamp.
GL20
12V
MR16 bi-pin base up to 20W
Available in black finish. Built-in
aluminum stake, patented pigtail
connector included.
Luma After-Sunset
®
Directional Lighting
Directional Lighting Order Information
GL23
12V
PAR36 25–50W
Directional well light moves up and
down tube. Patented pigtail connector
included. Black finish only.
Accessories: TAH13-*, TAF13-*,
TAL15 (Page 205)
GL23S
12V
PAR36 25–50W
Directional well light (does not move
up and down tube). Patented pigtail
connector included. Black finish only.
Accessories: GA01-*, GA03-*,
TAF4-* (Pages 201 & 205)
Catalog
Wattage/
Stake
Number Finish Volts Lamp Type
Included
GL20-BK Black 12 20W MR16 bi-pin base†
Built-in
GL23-BK Black 12 25–50W PAR36†
GL23S-BK Black 12 25–50W PAR36†
† Order lamp separately.
See descriptions below for additional dimension and mounting information.
UL Listed for wet locations.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 286–287
5.3"
(13 3 m m)
8"
( 203 mm )
4.8"
(12 1 m m)
2.5"
( 64 mm )
5.6"
(14 3 m m)
2.4"
(60 mm)
3.4"
(86 mm)
1.9"
(48 mm)
9.4"
(238 mm)
1"
( 25 m m )
7"
( 178 m m)
5.6"
( 143 mm )
GL23
GL23S
GL20
NPPG 192
www.ruudlighting.com
pg_0011
NPPG 193
193
Wall Lighting
A stucco wall, basket-weave or stone
exterior are ideal surfaces to light
because of the inherent surface
changes. Provides security as well
as aesthetic appeal. Position fixtures
12"–24" (305–610 mm) from the wall
for a scalloped effect. Position fixtures
3"–6" (76–152 mm) from the wall for
a grazed high relief effect. Use flood
or wide flood lamp.
GL80
12V
MR16 bi-pin thru 50W
Available in black or verde DeltaGuard
finish. Stake and patented pigtail
connector included.
Luma After-Sunset
®
Directional Flood
Directional Flood Order Information
GL81
12V
PAR36 thru 75W
Available in black or verde DeltaGuard
®
finish. Stake and patented pigtail
connector included.
Catalog
Wattage/
Number Finish Volts Lamp Type
GL80-BK Black 12 MR16 bi-pin base thru 50W†
GL80-VE Verde 12 MR16 bi-pin base thru 50W†
GL81-BK Black 12 PAR36 thru 75W†
GL81-VE Verde 12 PAR36 thru 75W†
† Order lamp separately.
Mounting Accessories (Field-installed)
Description
Catalog #
Single Mount Cast Junction Box Cover (for 1 fixture) DAF-JB1
(a)
Dual Mount Cast Junction Box Cover (for 2 fixtures) DAF-JB2
(a)
(a)
Specify Finish Color:
BK
= Black,
VE
= Verde
Ground Mount Post
PGM-1BK
Conduit Slipfitter (can be used with Ground Mount Post) MNH-2BK
Fixture Accessories (Field-installed)
Description
Catalog #
Color Filters (for use with GL80 fixtures)
DAF-CF1*
Color Filters (for use with GL81 fixtures)
DAF-CF4*
* Specify color: Red (R), Green (G), Amber (A), Blue (B)
UL Listed for wet locations.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 286–287
6 .5 "
(1 65 m m)
2 .9 "
(73 mm)
3 .9 "
(98 mm)
2. 6"
(6 5 mm )
T h rea de d En d
1 /2 "-1 4 N PSM
0 .7 5" ( 19 m m)
GL80
1 0. 9"
( 27 6 mm)
5 .5 "
(1 4 0 mm)
2 "
( 51 mm)
2. 6"
(6 5 mm)
T h re a d ed E nd
1 /2 " -1 4 NP SM
0 .7 5 " ( 19 mm)
GL81
www.ruudlighting.com
pg_0012
NPPG 194
194
Column Lighting
Trace the fluting of a Corinthian column
all the way up to the ornate capital; or
direct streams of light up to accentuate
textured brick columns. Use narrow or
very narrow spot lamps.
DAU-GS
External Glare Shield
Cast-aluminum shield with black
DeltaGuard
®
finish eliminates glare for
pedestrian and vehicular traffic. Easily
attaches to top cover of fixture with four
furnished black stainless-steel screws.
DAU-LG
External Linear Grate
Cast-aluminum grate with black
DeltaGuard finish provides cutoff and
glare control and protects lens from
falling objects. Easily attaches to top
cover of fixture with four furnished black
stainless-steel screws.
Luma After-Sunset
®
Sealed Well Light
Sealed Well Light Order Information
DAU-HL
Hex Cell Louver
Reduces side glare. Mounts internally
to top cover with three furnished clips.
TA084
Cutoff Baffle
For use with MR16 lamp. Provides
sharp cutoff. Installs inside fixture onto
lamp holder.
0.5"
(13 mm)
0.40"
(10 mm)
0.40"
(10 mm)
6.2"
(157 mm)
5.3"
(133 mm)
6.3" (160 mm)
TAF1*
Color Filter (1.9" dia./49 mm)
For use with MR16 lamps. Installs
inside fixture onto lamp holder.
* Specify color: Red (R), Green (G),
Amber (A), Blue (B)
DAU-CF*
Color Filter (4.7" dia./119 mm)
Mounts internally to top cover with three
furnished clips.
* Specify color: Red (R), Green (G),
Amber (A), Blue (B)
Catalog
Wattage/
Number Finish Volts Lamp Type
GL70-BK Black 12 MR16 bi-pin base thru 75W†
GL71-BK Black 12 PAR36 thru 50W†
† Order lamp separately.
Note: Not suitable for concrete burial. Pea gravel required (not supplied) as back fill around fixture
for proper drainage.
Fixture Accessories (Field-installed)
Description
Catalog #
External Glare Shield
DAU-GS
Hex Cell Louver
DAU-HL
External Linear Grate
DAU-LG
Cutoff Baffle (for use with MR16 lamp)
TA084
Color Filters (for use with MR16 lamps; 1.9" dia./49 mm) TAF1*
Color Filters (for use with PAR36 lamp; 4.7" dia./119 mm) DAU-CF*
Mounts internally to top cover with three furnished clips
* Specify color: Red (R), Green (G), Amber (A), Blue (B)
UL Listed for wet locations.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
Fixture Accessories
NPPG 194
www.ruudlighting.com
pg_0013
NPPG 195
195
Step Lighting–Embedded
Three designs with three finish choices
each, Luma fixtures will complement brick,
stone or wood stair walls. 2' (0.6 m) circle
of light at 2' (0.6 m) mounting height.
NOTE: Cannot be embedded in concrete.
GL50
12V
Available in black or verde finish.
Patented pigtail connector & 13W #93
lamp included.
Maximum wattage: 13W #93.
NS6213 (13W)
12V
Fixture shown with Wire Guard Acc.
12V with electronic ballast.
Available in black.
13W twin tube 4-pin compact
fluorescent lamp included.
Mounting: 1/2" threaded swivel.
12V: GA07 friction-fit coupling/stake
assembly & patented pigtail connector
included.
Accessories: DB-9BK, FWG-9, GA22,
GS-9BK, MNB-2BK, MNH-2BK
(Pages 201 & 205)
NS6226 (26W)
12V
12V with electronic ballast. Available in
black.
26W Quad tube 4-pin compact
fluorescent lamp included. Mounting:
1/2" threaded swivel.
12V: GA07 friction-fit coupling/stake
assembly & patented pigtail connector
included.
Accessories: DB-9BK, FWG-9, GA22,
GS-9BK, MNB-2BK, MNH-2BK
(Pages 201 & 205)
Luma After-Sunset
®
Specialty Lighting
Specialty Lighting Order Information
GL51
12V
Available in black or verde finish.
Patented pigtail connector &
(2) 13W #93 lamps included.
Maximum wattage: (2) 13W #93.
GL55
12V
MR16 bi-pin base 20W
Available in solid brass, black or verde
finish. Order lamp separately. Patented
pigtail connector included.
Downlight only.
Catalog
Wattage/
Number
Finish Volts Lamp Type
GL50-BK
Black 12
13W #93*
GL50-VE
Verde 12
13W #93*
GL51-BK
Black 12
(2)13W #93*
GL51-VE
Verde 12
(2)13W #93*
GL55-BK
Black 12
20W MR16
bi -pi n ba s e
GL55-VE
Verde 12
20W MR16
bi- pin ba se
GL55-SPB Solid Brass 12
20W MR16
bi -pi n ba s e
NS6213-LBK Black 12
13W Twin Tube FL*
NS6226-LBK Black 12
26W Quad Tube FL*
NOTE: NS Series fixtures include internal step-up transformer and GA07 mounting stake.
*Lamp(s) included.
† Order lamp separately.
UL Listed for wet locations.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
Ro ug h- in op en ing :
2. 25 " x 4 . 12 5"
(
57 m m x 1 05 mm
)
T o p Vie w
5 "
( 12 7 mm)
1 . 9"
( 4 8 mm)
0 . 37 5"
( 10 m m)
3. 3 "
( 83 m m)
4.75"
(121 mm)
6.25"
(159 mm)
9.75"
(248 mm)
GL50
NS6
GL51
GL55
2. 3"
( 57 m m )
3.3 "
( 83 m m )
9 .5"
( 241 m m )
R ou gh -in o pe ni ng:
2. 37 5" x 8 .1 25 "
(6 0 m m x 206 m m )
T op V iew
0.37 5"
( 10 m m )
4. 3"
(10 8 mm)
4"
(102 mm)
4. 3"
(10 8 mm)
R oug h-in o pen ing : 4 " o cta gon
4. 3"
(10 8 mm)
3 .1 "
(7 9 mm)
F ront View
Si de Vie w
www.ruudlighting.com
pg_0014
NPPG 196
196
Break Away from
Linear Limits
Forget all your conventional
ideas about track lighting. The
Luma Low-Voltage (12V) Track
Lighting System from Ruud
®
lets your creativity flow.
First, this system is UL Listed
in the US and Canada for wet
locations, which immediately
sets it apart from all the others.
Second, Luma Low-Voltage
Lighting isn’t confined to the
rigid straight runs of traditional
track. You don’t have to limit
your layout concepts. If your
project involves columns and
curves, and you seek a lighting
system that flows with these
organic shapes, then Luma
Low-Voltage fits the spec.
With this system, lighting goes
where it has never gone before.
Of course, it also performs
brilliantly in straight lengths or
90-degree turns as well!
Lo
w
-V
oltage Track
TRB1E-LWH Luma Track Fixtures
Page 199
TL013 Luma Track Fixtures
Page 198
www.ruudlighting.com
pg_0015
NPPG 197
197
Luma
Low-Voltage (12V)
Track Lighting System
Create shapes and outlines
that haven’t been possible
before, in areas where
traditional track is not
permitted. That’s what the
Luma Track System is all
about.
The System Elements
The Luma Low-Voltage Track
Lighting System is
comprised of four
components: track,
transformer, 10/3 cable and
fixtures.
1. Low-Voltage Fixtures
You’ll get crisp point-source
lighting with high CRI
values, using MR11, MR16,
PAR36 and T3 lamps. Luma’s
small halogen-lamp fixtures
produce sparkle
inconspicuously. Each fixture
is carefully built and
precision-finished.
2. Luma Track
Select extruded aluminum
track in 4-foot or 8-foot (1.2
or 2.4 m) lengths, or
economical PVC track in 4-
foot (1.2 m) lengths; both are
available in black or white.
See page 200.
To accommodate
applications with corners or
curves, Luma 10/3 cable can
be used without track and
secured with our TR1 (PVC)
or TRA1 (Aluminum) Cable
Holder accessory.
See page 200.
3. Remote Transformers
Choose either 300-watt or
600-watt capacity. 12-volt,
dual-circuit transformer is
supplied with a 6-foot
(1.8 m) cord and plug.
See page 186.
4. Flexible Cable
We use self-sealing, #10
gauge, 3-wire cable to allow
longer runs without typical
voltage drop (see page 187
for information on voltage
drop and cable runs).
Our patented connector
allows quick and easy
connections without cutting
or splicing cable.
Connector
Connector Cover
Pigtail
Wires
3-Wire Main Cable
Connector Spine
or Track
Alternate direction
of connector for
2nd circuit
TLB09 Luma Track Fixtures
Page 207
www.ruudlighting.com
pg_0016
NPPG 198
198
Track System Order Information
TLO13
12V
PAR36 25–50W
Available in black or white.
.87" (22 mm)
2.37"
(61 mm)
4.62"
(118 mm)
Suitable for Outdoor Use
TMC2E-L
12V
MR16 bi-pin base 20–50W
Available in black or white.
1.73"
(44 mm)
2.36"
(60 mm)
3.37"
(86 mm)
1.9"
(48 mm)
TES1E-L
12V
MR16 bi-pin base 20–50W
Available in black or white.
1.87" (48 mm)
2.75" (70 mm)
4.0"
(102 mm)
Suitable for Outdoor Use
UL Listed
Catalog
Wattage/
in U.S. and
Number Finish Volts Lamp Type
Canada
TLO13-BK Black 12 25–50W PAR36† Wet Location
TLO13-WH White 12 25–50W PAR36† Wet Location
TMC2E-LBK Black 12 20–50W MR16
bi -pi n ba s e
† Wet Location
TMC2E-LWH White 12 20–50W MR16
bi -pi n ba s e
† Wet Location
TES1E-LBK Black 12 20–50W MR16
bi -pi n ba s e
† Damp Location
TES1E-LWH White 12 20–50W MR16
bi -pi n ba s e
† Damp Location
† Order lamp separately.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Luma Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 200
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
Outdoor Track-Patio Lighting
Patios open up with the addition of track
lighting. Fixtures can be located to
create specific seating areas or across
areas for general illumination. Fixtures
can be moved or added as needs arise.
Luma After-Sunset
®
Track System
TES1E-L
TMC2E-L
TL013
NPPG 198
www.ruudlighting.com
pg_0017
NPPG 199
199
TFB1E-L
12V
MR16 bi-pin base 20–50W
Available in black or white.
Track System Order Information
2 " (5 1 mm )
2 . 5" ( 64 m m)
4 .2 5"
(10 8 m m)
TLB09
12V
T3 bi-pin base 10W
Available in black or white.
. 8 7" (2 2 m m)
. 7 5" (1 9 m m)
1 . 5"
(38 mm )
1. 8 7"
(4 8 m m)
TLB07 & TLB07M
12V
TLB07: MR16 bi-pin base 20–75W
TLB07M: MR11 bi-pin base 20–35W
Available in black or white.
2 . 62 " (6 7 m m)
2 "
(5 1 m m)
1 . 12 " (2 9 m m)
M R1 6 S oc ket
Bi- Pin La mp
TNB1E-L
12V
MR16 bi-pin base 20–50W
Available in black or white.
1. 1 " (2 8 mm )
2 .7 " (6 9 m m)
2 . 65 "
(67 mm )
1 "
(2 5 m m)
TRB1E-L
12V
MR16 bi-pin base 20–50W
Available in black or white.
2" (51 mm)
2. 5 " (64 m m)
4 .2 5"
(10 8 mm)
Outdoor-Tree Lighting
Because Luma cable can be snaked up a
trellis or a tree, a lovely, natural
moonlighting effect can be achieved.
Light filters down from tree tops,
creating leafy shadows that change with
every night breeze. TC14 C-clamp
recommended when installing fixtures
in trees.
Luma After-Sunset
®
Track System
TLB07
TRB1E-L
TNB1E-L
TFB1E-L
TLBO9
2. 25 " (58 mm)
1. 5"
(3 8 mm )
. 6 2" (1 6 mm)
M R1 1/ 16 Socke t
Bi-P in L amp
TLB07M
UL Listed
Catalog
Wattage/
in U.S. and
Number Finish Volts Lamp Type
Canada
TFB1E-LBK Black 12 20–50W MR16
bi-p in bas e
† Damp Location
TFB1E-LWH White 12 20–50W MR16
bi-p in bas e
† Damp Location
TLB07-BK Black 12 20–75W MR16
bi-p in bas e
† Damp Location
TLB07-WH White 12 20–75W MR16
bi-p in bas e
† Damp Location
TLB07M-BK Black 12 20–35W MR11
bi-p in bas e
† Damp Location
TLB07M-WH White 12 20–35W MR11
bi-p in bas e
† Damp Location
TLB09-BK Black 12 5 or 10W T3
bi- pin ba se
† Damp Location
TLB09-WH White 12 5 or 10W T3
bi- pin ba se
† Damp Location
TNB1E-LBK Black 12 20–50W MR16
bi-p in bas e
† Damp Location
TNB1E-LWH White 12 20–50W MR16
bi-p in bas e
† Damp Location
TRB1E-LBK Black 12 20–50W MR16
bi-p in bas e
† Damp Location
TRB1E-LWH White 12 20–50W MR16
bi-p in bas e
† Damp Location
† Order lamp separately.
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Luma Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 200
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
www.ruudlighting.com
pg_0018
NPPG 200
200
PVC Track is an economical choice for use with small fixtures such as the TLB09; for
larger fixtures, such as the TLO13, we recommend additional fasteners be used to
support the track. In finished, exposed locations, we recommend aluminum track. It is
more rigid than PVC and will not discolor from exposure to sunlight and weather.
Luma After-Sunset
®
Track Order Information
Catalog
Endcaps
Number Style Finish Included Length
TRA4-BK Aluminum Black 1 4' (1.2 m)
TRA4-WH Aluminum White 1 4' (1.2 m)
TRA8-BK Aluminum Black 1 8' (2.4 m)
TRA8-WH Aluminum White 1 8' (2.4 m)
TR4-BK PVC
Black 1 4' (1.2 m)
TR4-WH PVC
White 1 4' (1.2 m)
For mounting cable to trees, soffits, etc.
Spine/Cable Holder
TRA1-BK Aluminum Black – 1.5" (38 mm)
TRA1-WH Aluminum White – 1.5" (38 mm)
TR1-BK PVC
Black – 1.5" (38 mm)
TR1-WH PVC
White – 1.5" (38 mm)
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 185
Transformers and Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 186–187
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 201–205
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
1.0" (25 mm)
1.0"
(25 mm)
0.8" (20 mm)
0.6"
(15 mm)
Extruded
Aluminum Track
Connector
Connector Pins
10/3 Cable
0.625" (16 mm) wide
x .300" (8 mm) high
Attachment Screw
Top
Bottom
Cable Sold
Separately
NPPG 200
www.ruudlighting.com
pg_0019
NPPG 201
201
Catalog# Description
DAF-JB1
(a)
Single Mount Cast
Junction Box Cover (1 fixture)
DAF-JB2
(a)
Dual Mount Cast
Junction Box Cover
(2 fixtures)
(a)
Specify Finish Color:
BK
= Black,
VE
= Verde.
For use with octagonal & single gang junction
boxes. Includes adapter plate. For GL80,
GL81.
Luma After-Sunset
®
— Mounting Accessories
Catalog# Description
GA05 Standard Stake
Black stake is PVC, 12" (305 mm) long with
anti-rotation fin. Included with GL09, GL44,
GL45, GL47, GL48, GL49.
Catalog# Description
GA07 Stake Assembly
Black stake is extruded 1/2" PVC, 12" (305 mm)
long. Push-type friction fit coupling/ stake
assembly. Included with GL41.
Catalog# Description
GA19 Stake Assembly
for bollard
Black stake is extruded 1/2" PVC, 12" (305 mm)
long. Push-type friction fit coupling/stake
assembly. Included with GL19, GL60, GL62.
Catalog# Description
GA08 Pigtail & Connector
1
8/2 SPT is 6' (1.8 m) long, molded black
polycarbonate with nickel plated beryllium
copper contact pins. For converting other
manufacturers’ products to work on Luma
10-3 cable; to extend length of connectors.
TR1-12BK required if using 12/2 cable.
Catalog# Description
GA13-* Cable Connector
Allows for splicing of cable or cable runs off
of main cable. 150W per circuit maximum
through dual-cable connector. TR1-12BK
required if using 12/2 cable.
*Specify BK=Black, WH=White.
Catalog# Description
GA22 Mounting
Canopy
4.3" dia. (108 mm). Cast aluminum and
gasketed; finish color black. 2 screws
supplied. Allows for mounting of fixtures
equipped with 1/2" adjustable fitter.
Catalog# Description
MNB-2BK Mounting Box with
Stake, Cord and Plug
Cast aluminum black box provides enclosed
wiring chamber. 6.5" (165 mm) aluminum
stake; 10' (3.0 m) gasketed cord; 120V
straight blade plug.
Catalog# Description
MNH-2BK 2" Conduit
Slipfitter
Cast aluminum black hub provides threaded
entry. Slips over 2-3/8" O.D. pipe or tenon.
3/8" allen set screw secures slipfitter.
Catalog # Description
PGM-1BK Ground Mount Post
Use with Conduit Slipfitter (MNH-2BK)
for ground mounted fixtures. Wiring or
conduit feeds through post base.
Overall: 24"H (610 mm)
Tube: 18"H x 2.4"D (457 x 60 mm)
Base: 4.9"W x 6.3"L (124 x 159 mm)
Single Mount
Junction Box Cover
Dual Mount
Junction Box
Cover
1.5"H x 4.4" dia. (38 x 113 mm)
www.ruudlighting.com
pg_0020
NPPG 202
202
Luma After-Sunset
®
Track — Mounting Accessories
Catalog# Description
TC1-* Feed Thru Box
5"sq. (plate) x 4"sq. x 0.6"H (cover) (127 x
102 x 16 mm). For cleaner appearance at a
corner or at a cable entry location. One end
supplied open, three knockouts provided.
*Specify color: BK=Black, WH=White.
Catalog# Description
TC2-* Corner Cover
TC4-* End Feed Cover
TC2: 3.3" x 3.3" (83 x 83 mm). For cleaner
appearance where two tracks meet at 90°.
TC4: 2.4"L x 0.9"W x 0.6"H (60 x 24 x 16 mm).
Snaps-on for cleaner appearance at track end.
*Specify color: BK=Black, WH=White.
Catalog# Description
TC3-* Track End Cap
TC9-WH Mounting Clip 9/16"
TC15-WH Mounting Clip 15/16"
TC16 1/4" Drop Tile Spacer
TC3: For cleaner appearance at track end.
TC9/TC15: For attaching track to T-Bar
ceiling.
*Specify color: BK=Black,WH=White.
Catalog# Description
TC14-* C-clamp
Provides additional security for attachment of
track head to track or cable holder (TR1 or
TRA1). Recommended for track installed in
trees, under exterior soffits, etc.
*Specify color: BK=Black, WH=White.
Catalog# Description
TR1-12BK PVC spine 12/2
(qty: 20)
Adapts 2-wire cable to Luma 3-wire system.
Use one per fixture for secure connection.
TC4
TC2
TC9/TC15
TC3
TC16
NPPG 202
www.ruudlighting.com
pg_0021
NPPG 203
203
Luma After-Sunset
®
— Fixture Accessories
203
Color Filter
Catalog # Lampholder
TAF1* MR16
• 1.9" dia. (49 mm)
*Specify color: B=Blue, R=Red, G=Green,
A=Amber.
TES1E-L
TFB1E-L
TRB1E-L
TNB1E-L
Cutoff Baffle
Catalog # Lampholder
TA084 MR16
• 1.4" dia. x 1.3" L (35 x 32 mm)
Eliminates side glare, narrows wide flood.
Clear Lens
Catalog # Lampholder
TA080 MR16
• 1.9" dia. (49 mm)
Spread Lens
Catalog # Lampholder
TA081 MR16
• 1.9" dia. (49 mm)
Reduces concentric circles. Creates wide
beam pattern.
Linear Spread Lens
Catalog # Lampholder
TA082 MR16
• 1.9" dia. (49 mm)
Elongates beam pattern.
Soft Focus Lens
Catalog # Lampholder
TA083 MR16
• 1.9" dia. (49 mm)
Reduces concentric circles. Maintains lamp’s
original beam pattern.
Accessories for use on
TES1E-L, TFB1E-L,
TRB1E-L, TNB1E-L
(MR16 bi-pin base lampholder)
Hexcell Louver
Catalog # Lampholder
TA031 MR16
• 1.9" dia. (49 mm)
www.ruudlighting.com
pg_0022
NPPG 204
204
Luma After-Sunset
®
— Fixture Accessories
Catalog# Description
TAL06S Holder/Louver
Catalog# Description
DAF-CF1* Color Filter
Installs inside fixture onto lamp holder.
2.2" dia. (55 mm).
*Specify color: R=Red, G=Green, A=Amber,
B=Blue.
Catalog# Description
TAF1* Color Filter
1.9" dia. (49 mm). *Specify color: B=Blue,
R=Red, G=Green, A=Amber.
TLB07
Accessories for use on
TLB07
(MR16 bi-pin base
lampholder)
GL80
Accessories for use on
GL80
(MR16 bi-pin base
lampholder)
Catalog# Description
DAF-CF4* Color Filter
Installs inside fixture onto lamp holder.
4.8" dia. (122 mm).
*Specify color: R=Red, G=Green, A=Amber,
B=Blue.
GL81
Accessories for use on
GL81
(PAR36 lampholder)
NPPG 204
www.ruudlighting.com
pg_0023
NPPG 205
205
Luma After-Sunset
®
— Fixture Accessories
GL23S
GL23
TLO13
Accessories for use on
GL23, TLO13
(PAR36 lampholder)
Accessories for use on
GL23S
(PAR36 lampholder)
Accessories for use on
NS Series
Catalog# Description
TAH13-* Louver/Filter Holder
Black or White
4.6" dia. (116 mm).
*Specify color: BK= Black, WH=White.
Catalog# Description
TAF13-* Color Filter
4.7" dia. (114 mm). For use with TAH13
Louver/Filter Holder.
*Specify color: C=Clear, B=Blue, G=Green,
A=Amber.
Catalog# Description
TAL15 Black Hex Cell
Louver
4.6" dia. (116 mm). For use with TAH13
Louver/Filter Holder.
Catalog# Description
GA01-BK Black Cast
Aluminum Grate
6.2" dia. (158 mm).
Catalog# Description
GA03-BK Black Cast
Aluminum Lens Holder
6.2" dia. (158 mm).
Catalog# Description
TAF4* Convex Lens
5.6" dia.(143 mm). Use with GA03 Lens
Holder. *Specify Color: C=Clear, B=Blue,
R=Red, G=Green, A=Amber.
Catalog# Description
DB-9BK Deep Baffle
Aluminum with black DeltaGuard
®
finish.
10.1"W x 6.3"L x 3.5"D (257 x 160 x 89 mm).
Catalog# Description
FWG-9 Wire Guard
9.6"L x 6.1"W x 1.5"D. (245 x 156 x 89 mm).
1" (25 mm) spacing between steel wires.
Catalog# Description
GS-9BK Glare Shield
Aluminum with black DeltaGuard finish.
www.ruudlighting.com
pg_0024
NPPG 206
206
A
ccen
t/Lan
dscape
Directional Floodlight
Blending contemporary styling
with rugged, die-cast aluminum
construction, the Directional
Flood (DF Series) provides
specifiers and electrical
contractors with many practical
and exciting options. This
versatile product is available in
line-voltage PAR20, PAR30 and
PAR38 and G12 base lamps.
Sealed Well Light
The Sealed Well Light (DU
Series) exemplifies common-
sense design, outstanding
performance and rugged
construction. The adjustable
internal lamp of the fixture
provides easy aiming, with
cutoff control for any project.
The Incandescent (DU1 Series)
uses MR16, PAR36 or
PAR20/30/38 lamp types. An
HID fixture (DU4/5 Series) is
available with a choice of
PAR30, PAR38 and G12 base
lamps in metal halide or an
ED17 version in either metal
halide or high pressure
sodium.
Micro Flood
These compact, easy-to-install
fixtures provide excellent
performance for smaller-scale
applications. The parabolic
optical system provides
efficient floodlighting for
building surfaces and wall
areas. The fixture, with a sturdy
die-cast housing, is available in
120 voltage, 13-watt or 26-watt
fluorescent.
DF Series Fixtures (Directional Flood)
Page 208
DF Series Fixtures (Directional Flood)
Pages 215–216
www.ruudlighting.com
pg_0025
NPPG 207
207
207
Directional Flood—Incandescent
DF Series Order Information
Catalog
Wattage/
Number
Profile
Finish Lamp Type
Surface Mount
DF1P20F-1BK Flat
Black PAR20 thru 50W†
DF1P20F-1WH Flat
White PAR20 thru 50W†
DF1P20S-1BK Shroud
Black PAR20 thru 50W†
DF1P20S-1WH Shroud
White PAR20 thru 50W†
DF1P30F-1BK Flat
Black PAR30 thru 75W†
DF1P30F-1WH Flat
White PAR30 thru 75W†
DF1P30S-1BK Shroud
Black PAR30 thru 75W†
DF1P30S-1WH Shroud
White PAR30 thru 75W†
DF1P38F-1BK Flat
Black PAR38 thru 150W†
DF1P38F-1WH Flat
White PAR38 thru 150W†
DF1P38S-1BK Shroud
Black PAR38 thru 150W†
DF1P38S-1WH Shroud
White PAR38 thru 150W†
DF1P38S-1VE Shroud
Verde PAR38 thru 150W†
In-Ground Mount
DF1M16F-1BK Flat
Black MR16 thru 75W†
DF1M16F-1VE Flat
Verde MR16 thru 75W†
DF1M16S-1BK Shroud
Black MR16 thru 75W†
DF1M16S-1VE Shroud
Verde MR16 thru 75W†
DF1P36F-1BK Flat
Black PAR36 thru 75W†
DF1P36S-1BK Shroud
Black PAR36 thru 75W†
† Order lamp separately.
Mounting Accessories (Field-installed)
Description
Catalog #
10" (254 mm) Mounting Extension
DAF-EXT10BK
20" (508 mm) Mounting Extension
DAF-EXT20BK
30" (762 mm) Mounting Extension
DAF-EXT30BK
Single Mount Cast Junction Box Cover (for 1 fixture)
DAF-JB1
(a)
Dual Mount Cast Junction Box Cover (for 2 fixtures)
DAF-JB2
(a)
Button Photocell (order with Cast Junction Box Cover) PC-1
Ground Mount Post
PGM-1BK
Conduit Slipfitter (can be used with Ground Mount Post) MNH-2BK
Mounting Box with Stake, Cord & Plug
MNB-2BK
(a)
Specify Finish Color:
BK
= Black,
VE
= Verde,
WH
= White
Fixture Accessories (Field-installed)
Description
Catalog #
Color Filter (for MR16 fixtures; 2.2" dia./55 mm)
DAF-CF1*
Color Filter (for PAR20 fixtures; 2.6" dia./65 mm)
DAF-CF2*
Color Filter (for PAR30 fixtures; 3.7" dia./84 mm)
DAF-CF3*
Color Filter (for PAR36/38 fixtures; 4.8" dia./122 mm) DAF-CF4*
* Specify color: Red (R), Green (G), Amber (A), Blue (B)
UL Listed for wet locations.
Low Voltage (12V) Directional Flood Fixtures . . . . . . . . . . . . . . . . . . . . . . . . Page 193
Accessories & Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 209
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
DF1P30F-1 Flat Profile
PAR30 thru 75W, 120V
Size: 6.5"L x 7.3"H x 4.4" dia.
(165 x 184 x 111 mm)
DF1P30S-1 Shrouded Profile
PAR30 thru 75W, 120V
Size: 9.7"L x 7.3"H x 4.4" dia.
(246 x 184 x 111 mm)
DF1P38F-1 Flat Profile
PAR38 thru 150W, 120V
Size: 7.0"L x 7.5"H x 5.5" dia.
(178 x 191 x 140 mm)
DF1P38S-1 Shrouded Profile
PAR38 thru 150W, 120V
Size: 10.9"L x 7.5"H x 5.5" dia.
(276 x 191 x 140 mm)
DF1P20S-1 Shrouded Profile
PAR20 thru 50W, 120V
Size: 7.8"L x 6.5"H x 3.3" dia.
(197 x 165 x 83 mm)
Surface Mount
(shown with Cast Junction Box Cover—order separately)
DF1P20F-1 Flat Profile
PAR20 thru 50W, 120V
Size: 5.4"L x 6.5"H x 3.3" dia.
(137 x 165 x 83 mm)
DF1P36S-1 Shrouded Profile
PAR36 thru 75W,120V
Transformer and wiring compartment
included. Also available in Flat Profile.
Head Size: 10.9"L x 7.5"H x 5.5" dia.
(277 x 191 x 140 mm)
DF1M16S-1 Shrouded Profile
MR16 bi-pin thru 75W,120V
Transformer, wiring compartment and
1/2" adjustable fitter included. Also
available in Flat Profile.
Head Size: 6.5"L x 6.8"H x 2.9"dia.
(165 x 171 x 73 mm)
In-Ground Mount
(Pea gravel required (not supplied) as back fill around fixture for proper drainage)
www.ruudlighting.com
pg_0026
NPPG 208
NPPG 208
Pea gravel required (not supplied) as back
fill around fixture for proper drainage.
208
Directional Flood—HID
Lamp
Included!
DF Series Order Information
Wattage/ Finish Flat-Flood
Shrouded-Spot
Lamp Type
Catalog Number Catalog Number
In-Ground Mount
35W CMH, PAR20 Black DFA703-DFBK
DFD703-DSBK
35W CMH, PAR20 Verde DFA703-DFVE
DFD703-DSVE
70W CMH, PAR30 Black DFB707-DFBK
DFE707-DSBK
70W CMH, PAR30 Verde DFB707-DFVE
DFE707-DSVE
70W MH, G12* Black DFU407-DFBK
DFV407-DSBK
70W CMH, G12* Black DFU707-DFBK
DFV707-DSBK
70W MH, G12* Verde DFU407-DFVE
DFV407-DSVE
70W CMH, G12* Verde DFU707-DFVE
DFV707-DSVE
100W MH, PAR38 Black DFC410-DFBK
DFF410-DSBK
100W MH, PAR38 Verde DFC410-DFVE
DFF410-DSVE
Surface Mount
35W CMH, PAR20 Black DFG703-DFBK
DFK703-DSBK
35W CMH, PAR20 White DFG703-DFWH
DFK703-DSWH
70W CMH, PAR30 Black DFH707-DFBK
DFL707-DSBK
70W CMH, PAR30 White DFH707-DFWH
DFL707-DSWH
70W MH, G12* Black DFW407-DFBK
DFX407-DSBK
70W CMH, G12* Black DFW707-DFBK
DFX707-DSBK
70W MH, G12* White DFW407-DFWH
DFX407-DSWH
70W CMH, G12* White DFW707-DFWH
DFX707-DSWH
100W MH, PAR38 Black DFJ410-DFBK
DFM410-DSBK
100W MH, PAR38 White DFJ410-DFWH
DFM410-DSWH
Remote Mount (Maximum ballast to lamp lead distance is 20')
70W MH, G12* Black DFY407-DFBK
DFZ407-DSBK
70W CMH, G12* Black DFY707-DFBK
DFZ707-DSBK
70W MH, G12* White DFY407-DFWH
DFZ407-DSWH
70W CMH, G12* White DFY707-DFWH
DFZ707-DSWH
100W MH, PAR38 Black DFQ410-DFBK
DFT410-DSBK
100W MH, PAR38 White DFQ410-DFWH
DFT410-DSWH
* Includes new parabolic reflector.
Options (Factory-installed):
Change Add After
Suffix To Suffix
Button Photocell (120V, 277V or 347V)
1, 2 or 6 P
(Surface Mount only)
Mounting Accessories (Field-installed)
10" (254 mm) Mounting Extension
DAF-EXT10BK
20" (508 mm) Mounting Extension
DAF-EXT20BK
30" (762 mm) Mounting Extension
DAF-EXT30BK
Fixture Accessories (Field-installed)
Description
Catalog #
Color Filter (for PAR20 fixtures; 2.6" dia./65 mm)
DAF-CF2*
Color Filter (for PAR30 fixtures; 3.7" dia./94 mm)
DAF-CF3*
Color Filter (for PAR38 fixtures; 4.8" dia./122 mm)
DAF-CF4*
Linear Spread Lens (for PAR38 or G12 fixtures; 4.7" dia/119 mm) DAF-LSL
* Specify color: Red (R), Green (G), Amber (A), Blue (B)
UL Listed for wet locations. NOTE: -D voltage = 120/277V
Low Voltage (12V) Directional Flood Fixtures . . . . . . . . . . . . . . . . . . . . . . . . Page 193
Accessories & Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 209
Mounting Options
Shrouded Profile—Spot Lamp
35W PAR20 CMH, 120/277V
Size: 7.8"L x 6.5"H x 3.3" dia.
(197 x 165 x 83 mm)
Shrouded Profile—Spot Lamp
70W PAR30 CMH, 120/277V
Size: 9.7"L x 7.3"H x 4.4" dia.
(246 x 184 x 111 mm)
Flat Profile—Flood Lamp
35W PAR20 CMH, 120/277V
Size: 5.4"L x 6.5"H x 3.3" dia.
(137 x 165 x 83 mm)
Flat Profile—Flood Lamp
70W PAR30 CMH, 120/277V
Size: 6.5"L x 7.3"H x 4.4" dia.
(165 x 184 x 111 mm)
Shrouded Profile—Spot Lamp
100W PAR38 MH, 120/277V
Size: 10.9"L x 7.5"H x 5.5" dia.
(276 x 191 x 140 mm)
Flat Profile—Flood Lamp
100W PAR38 MH, 120/277V
Size: 7.0"L x 7.5"H x 5.5" dia.
(178 x 191 x 140 mm)
In-Ground Mount
Surface Mount
(wall or soffit)
Remote Mount
Electrical connections between remote mount ballast compartment and junction box
supplied by others.
Includes:
Single Mount
Junction Box
Cover
www.ruudlighting.com
pg_0027
7.75"
(197 mm)
3.25"
3.25"
(83 mm)
(83 mm)
5.375"
(FLAT)
(137 mm)
9.675"
(246 mm)
4.375"
2.88"
(111 mm)
(73 mm)
(FLAT)
6.5"
(165 mm)
(276 mm)
5.5"
2"
(140 mm)
(51 mm)
(FLAT)
7"
(178 mm)
10.875"
MR16
PAR20
PAR30
PAR36/38
4.5"
(FLAT)
(114 mm)
6.5"
(165 mm)
2.875"
3.875"
(73 mm)
(98 mm)
NPPG 209
209
Accessories, Dimensions—DF Series
Mounting Box with
Stake, Cord and Plug
Cat.#
MNB-2BK
Cast-aluminum black box provides
enclosed wiring chamber for 120V DF
fixture. 6.5" (165 mm) aluminum stake;
10' (3 m) gasketed cord; 120V straight
blade plug. For Incandescent DF Series
fixtures.
Ground Mount Post
Cat.#
PGM-1BK
Use with 2" Conduit Slipfitter for ground
mounted fixtures. Wiring or conduit
feeds through post base.
Overall: 24"H (610 mm)
Tube: 18"H x 2.4"D (457 x 60 mm)
Base: 4.9"W x 6.3"L (124 x 159 mm)
For Incandescent DF Series fixtures.
Catalog# Description
DAF-JB1
(a)
Single Mount Cast
Junction Box Cover (1 fixture)
DAF-JB2
(a)
Dual Mount Cast
Junction Box Cover
(2 fixtures)
PC-1 Button Photocell
(order with Cast Junction Box Cover where
knockout is provided)
(a)
Specify Finish Color:
BK
= Black,
VE
= Verde,
WH
= White
For use with octagonal & single gang
junction boxes. Includes adapter plate.
For Incandescent DF Series fixtures.
2" Conduit Slipfitter
Cat.#
MNH-2BK
Cast-aluminum black hub provides
threaded entry for 120V DF fixture. Slips
over 2-3/8" O.D. pipe or tenon. 3/8"
allen set screw secures slipfitter. Can
be used with PGM-1BK Ground
Mount Post. For Incandescent DF
Series fixtures.
Mounting Extension
Cat.# Description
DAF-EXT10BK 10"
DAF-EXT20BK 20"
DAF-EXT30BK 30"
For Incandescent and HID
DF Series fixtures.
Color Filters
Lampholder Catalog #
MR16
DAF-CF1*
(2.2" dia./55 mm)
PAR20 DAF-CF2*
(2.6" dia./65 mm)
PAR30 DAF-CF3*
(3.7" dia./94 mm)
PAR36/38 DAF-CF4*
(4.8" dia./122 mm)
For use with DF Series fixtures.
*Specify color: B=Blue, R=Red, G=Green,
A=Amber.
Line Voltage Mounting Accessories
Fixture Accessories
Single Mount
Junction Box Cover
shown with
Photocell Accessory
Dual Mount
Junction Box
Cover
Dimensional Drawings
1.5"H x 4.4 dia. (38 x 113 mm)
12.6"
(321 mm)
Front View
3.8"
(95 mm)
11.3"
(286 mm)
4.8"
(120 mm)
Side View
3.5"
(89 mm)
Linear Spread Lens
Cat.#
DAF-LSL (4.7" dia./119 mm)
Elongates beam pattern.
For HID PAR38 or G12 DF Series
fixtures.
Fixture Adjustability
www.ruudlighting.com
pg_0028
NPPG 210
210
Lamp
Included!
DU Series Order Information
Catalog Wattage/
Beam Maximum
Number Lamp Type Spread Aiming Angle
DU107M16-1 MR16 thru 75W†—
±45°
DU107P36-1 PAR36 thru 50W†—
±20°
DU115P38-1 PAR30/38 thru 150W†—
±20°
DU703P30-DS 35W CMH, PAR30 Spot ±20°
DU703P30-DF 35W CMH, PAR30 Flood ±20°
DU707P30-DS 70W CMH, PAR30 Spot ±20°
DU707P30-DF 70W CMH, PAR30 Flood ±20°
DU407P38-DS 70W MH, PAR38 Spot ±20°
DU407P38-DF 70W MH, PAR38 Flood ±20°
DU407P38-DW 70W MH, PAR38 Wide Flood ±20°
DU407G-DS 70W MH, G12* Spot ±20°
DU407G-DF 70W MH, G12* Flood ±20°
DU707G-DS 70W CMH, G12* Spot ±20°
DU707G-DF 70W CMH, G12* Flood ±20°
DU410P38-DS 100W MH, PAR38 Spot ±20°
DU410P38-DF 100W MH, PAR38 Flood ±20°
DU410P38-DW 100W MH, PAR38 Wide Flood ±20°
DU405SYM-D 50W MH, ED17 **
DU410SYM-D 100W MH, ED17 **
DU505SYM-D 50W HPS, ED17 **
DU510SYM-M 100W HPS, ED17 **
† Order lamp separately. * Includes new parabolic reflector. ** Symmetric Reflector
NOTE: Not suitable for concrete burial. Pea gravel required (not supplied) as back fill around
fixture for proper drainage.
Accessories (Field-installed):
Description
Catalog #
External Glare Shield
DAU-GS
External Linear Grate
DAU-LG
Hex Cell Louver
DAU-HL
Cutoff Baffle (for use with MR16 lamps)
TA084
Color Filters (for use with MR16 lamps; 2.0" dia./50 mm) TAF1*
Color Filters (4.7" dia./119 mm))
DAU-CF*
Linear Spread Lens (4.7" dia. /119 mm)
DAU-LSL
23W Fluorescent Lamp, 3000K (use in DU115P38-1) L-223GS30
23W Fluorescent Lamp, 2700K (use in DU115P38-1) L-223GS27
* Specify color: Red (R), Green (G), Amber (A), Blue (B)
UL Listed for wet locations. NOTE: -D voltage = 120/277V
Low Voltage (12V) Sealed Well Light Fixtures . . . . . . . . . . . . . . . . . . . . . . . . Page 194
Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 286–287
DAU-LG
External Linear Grate
Cast-aluminum grate with black
DeltaGuard finish provides cutoff and
glare control and protects lens from
falling objects. Easily attaches to top
cover of fixture with four furnished black
stainless-steel screws.
DAU-GS
External Glare Shield
Cast-aluminum shield with black
DeltaGuard
®
finish eliminates glare for
pedestrian and vehicular traffic. Easily
attaches to top cover of fixture with four
furnished black stainless-steel screws.
TA084
Cutoff Baffle
For use with MR16 lamp. Provides
sharp cutoff. Installs inside fixture onto
lamp holder.
DAU-HL
Hex Cell Louver
Reduces side glare. Mounts internally to
top cover with three furnished clips.
Fixture Accessories
DU1 Series
DU4/5/7 Series
Halogen
MH/HPS
Sealed Well Light
HID Lamp
Included!
0 . 5 "
(1 3 mm)
0 . 4 "
(1 0 mm)
0 . 4 "
(1 0 mm)
1 7 . 6 "
(4 4 6 mm)
1 6 . 6 "
(4 2 3 mm)
0 . 4 "
(1 0 mm)
2 . 4 "
( 6 1 mm)
9 . 7 " (2 4 5 mm)
6 . 3 " (1 6 0 mm)
0 . 5 "
(1 3 mm)
0 . 4 "
(1 0 mm)
0 . 4 "
( 1 0 mm)
9 . 5 "
(2 4 1 mm)
8 . 6 "
(2 1 7 mm)
0 . 4 "
(1 0 mm)
2 . 4 "
( 6 1 mm)
9 . 7 " ( 2 4 5 mm)
6 . 3 " (1 6 0 mm)
DAU-CF*
Color Filter (4.7" dia./119 mm)
Mounts internally to top cover with three
furnished clips.
* Specify color: Red (R), Green (G),
Amber (A), Blue (B)
TAF1*
Color Filter (2.0" dia./50 mm)
For use with MR16 lamps. Installs
inside fixture onto lamp holder.
* Specify color: Red (R), Green (G),
Amber (A), Blue (B)
L-223GS30 (3000K)
L-223GS27 (2700K)
23W Fluorescent Lamp
Self ballasted lamp that can be used
in the DU115P38-1 fixture.
DAU-LSL
Linear Spread Lens
Elongates beam pattern.
4.7" dia. (119 mm)
NPPG 210
www.ruudlighting.com
pg_0029
NPPG 211
211
Micro Flood
Lamp
Included!
NS Series Order Information
Catalog
Wattage/
Number Finish Volts
Lamp Type
NS6213-ULBK Black
120
13W Twin Tube 4-pin
NS6226-ULBK Black
120
26W Quad Tube 4-pin
NOTE: 13W or 26W electronic ballast is used in these fixtures.
Mounting Accessories: (Field-installed)
Description
Catalog Number
Mounting Canopy
GA22
Mounting Box with Stake, Cord & Plug
MNB-2BK
Conduit Slipfitter
MNH-2BK
Fixture Accessories: (Field-installed)
Description
Catalog Number
Deep Baffle
DB-9BK
Wire Guard
FWG-9
Glare Shield
GS-9BK
UL Listed for wet locations.
Line Voltage HID NS Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 110
Low Voltage (12V) NS Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 195
DB-9BK
Deep Baffle
Aluminum with black DeltaGuard finish.
10.1"W x 6.3"L x 3.5"D
(257 x 160 x 89 mm).
FWG-9
Wire Guard
9.6"L x 6.1"W x 1.5"D
(245 x 156 x 37 mm).
1" (25 mm) spacing between steel
wires.
GS-9BK
Glare Shield
Aluminum with black DeltaGuard finish.
Fixture Accessories
Mounting Accessories
GA22
Mounting Canopy
4.3" dia. (108 mm). Cast aluminum and
gasketed; finish color black. 2 screws
supplied. Allows for mounting of
fixtures equipped with 1/2" adjustable
fitter.
MNB-2BK
Mounting Box with Stake,
Cord and Plug
Cast-aluminum black box provides
enclosed wiring chamber for 120V NS
fixture. 6.5" (165 mm) aluminum stake;
10' (3.0 m) gasketed cord; 120V
straight- blade plug.
MNH-2BK
2" Conduit Slipfitter
Cast-aluminum black hub provides
threaded entry for 120V NS fixture. Slips
over 2-3/8" O.D. pipe or tenon. 3/8"
allen set screw secures slipfitter.
4. 75 "
(1 21 m m)
6. 2 5"
( 159 mm)
9. 75"
(24 8 mm )
www.ruudlighting.com